The American journal of cardiology · 2024
Transcatheter Aortic Valve Replacement in Low Surgical Risk Patients: An Updated Metanalysis of Extended Follow-Up Randomized Controlled Trials.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Di Pietro Gianluca, Improta Riccardo, De Filippo Ovidio, Bruno Francesco, Birtolo Lucia Ilaria, Tocci Marco, Fabris Tommaso, Saade Wael, Colantonio Riccardo, Celli Paola, Sardella Gennaro, Esposito Giovanni, Tarantini Giuseppe, Mancone Massimo, D'Ascenzo Fabrizio
Аннотация
The long-term safety and effectiveness of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) in low surgical risk has not been evaluated in a pooled analysis. An electronic database search was conducted for randomized controlled trials with a maximal 5 years clinical and echocardiographic follow-up including low surgical risk patients who underwent TAVR or SAVR. We calculated odds ratio (OR) and 95% confidence intervals (CIs) using a random-effects model. Subgroups analysis was performed for permanent pacemaker implantation and paravalvular leaks. Three randomized controlled trials were included with a total of 2,611 low surgical risk patients (Society of Thoracic Surgeons score <4%). Compared with SAVR, the TAVR group had similar rates of all-cause mortality (OR 0.94,95% CI 0.65 to 1.37, p = 0.75) and disabling stroke (OR 0.84, 95% CI 0.52 to 1.36, p = 0.48). No significant differences were registered in the TAVR group in terms of major cardiovascular events (OR 0.96, 95% CI 0.67 to 1.38, p = 0.83), myocardial infarction (OR 0.69, 95% CI 0.34 to 1.40, p = 0.31), valve thrombosis (OR 3.11, 95% CI 0.29 to 33.47, p = 0.35), endocarditis (OR 0.71,95% CI 0.35 to 1.48, p = 0.36), aortic valve reintervention (OR 0.93, 95% CI 0.52 to 1.66, p = 0.80), and rehospitalization (OR 0.80, 95% CI 0.52 to 1.02, p = 0.07) compared with SAVR. However, TAVR patients had a higher risk of paravalvular leaks (OR 8.21, 95% CI 4.18 to 16.14, p <0.00001), but lower rates of new-onset atrial fibrillation (OR 0.27,95% CI 0.17 to 0.30, p <0.0001). The rates of permanent pacemaker implantation were comparable from 1 year up to a maximum of 5 years (OR 1.32, 95% CI 0.88 to 1.97, p = 0.18). Lastly, TAVR had a greater effective orifice area (0.10 cm2/m2, 95% CI 0.05 to 0.15, p = 0.0001), but similar transvalvular mean gradients (0.60, 95% CI 3.94 to 2.73, p = 0.72). In conclusion, TAVR patients had similar long-term outcomes compared with SAVR, except for an elevated risk of paravalvular leaks in the TAVR group and increased rates of atrial fibrillation in the SAVR cohort.