m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2024

Transcatheter Aortic Valve Replacement With the Navitor System: Real-World United Kingdom Experience.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bharucha Apurva H, Kanyal Ritesh, Mullen Michael, Patel Kush, Smith David, Shome Joy, Blackman Daniel J, Aktaa Suleman, Williams Paul D, Khogali Saib, Dworakowski Rafal, Eskandari Mehdi, Byrne Jonathan, MacCarthy Philip

Аннотация

The Navitor transcatheter heart valve (THV) is the latest iteration of the Portico self-expanding valve system. Early prospective studies have shown promising outcomes, however, there is a lack of complementary 'real-world' data. This study aimed to assess early safety and efficacy outcomes of the Navitor THV using registry data from 6 high-volume United Kingdom transcatheter aortic valve replacement (TAVR) centers. Demographic, procedural, and in-hospital outcome data were retrieved from 6 United Kingdom centers. The primary safety end point was 30-day mortality. Primary efficacy end points were procedural success, mean aortic gradient, and ≥moderate paravalvular leak. Secondary end points included rates of new permanent pacemaker implantation, stroke, and vascular injury. A total of 574 patients (mean age 83.4 years; 54.5% female) underwent Navitor TAVR between January 2020 and May 2023. The 30-day mortality in this patient cohort was 1.6%. Procedural success was 98.1%, mean echo-derived gradient post-TAVR was 7.7 ± 4.8 mm Hg (95% confidence interval [CI] 7.2 to 8.3, p <0.001) and 5.1% of patients had ≥moderate paravalvular leak (sample proportion estimate [p̂] = 0.051, 95% CI [0.035, 0.073], p <0.001). New permanent pacemaker implantation to discharge was required in 11% (p̂ = 0.119, 95% CI 0.088 to 0.158, p <0.001), stroke occurred in 1.2% of patients (p̂ = 0.017, 95% CI 0.006 to 0.036, p <0.001) and significant vascular injury in 1.6% (p̂ = 0.014, 95% CI 0.005 to 0.032, p <0.001). In conclusion, early procedural outcomes with Navitor TAVR compare favorably to new-generation THVs. Procedural success was high with a low incidence of complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты