Improved Hemodynamics With Self-Expanding Compared to Balloon-Expandable Transcatheter Aortic Valve Implantation in Small Annulus Patients: A Propensity-Matched Analysis.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Baudo Massimo, Sicouri Serge, Yamashita Yoshiyuki, Ridwan Khalid, Kadri Amer, Goldman Scott M, Rodriguez Roberto, Gnall Eric M, Coady Paul M, Reardon Michael J, Gada Hemal, Gray William A, Ramlawi Basel

Аннотация

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты