MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/nejmoa2312573

Медицинская библиотека · The New England journal of medicine · 2024

Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus.

Herrmann Howard C, Mehran Roxana, Blackman Daniel J, Bailey Stephen, Möllmann Helge, Abdel-Wahab Mohamed, Ben Ali Walid, Mahoney Paul D, Ruge Hendrik, Wood David A, Bleiziffer Sabine, Ramlawi Basel, Gada Hemal, Petronio Anna Sonia, Resor Charles D, Merhi William, Garcia Del Blanco Bruno, Attizzani Guilherme F, Batchelor Wayne B, Gillam Linda D, Guerrero Mayra, Rogers Toby, Rovin Joshua D, Szerlip Molly, Whisenant Brian, Deeb G Michael, Grubb Kendra J, Padang Ratnasari, Fan Myra T, Althouse Andrew D, Tchétché Didier, SMART Trial Investigators

СтатьяРандомизированное исследованиеМногоцентровое исследованиеСравнительное исследованиеEquivalence TrialПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR).

METHODS

We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority).

RESULTS

A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups.

CONCLUSIONS

Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).

Для цитирования: Herrmann Howard C, Mehran Roxana, Blackman Daniel J, Bailey Stephen, Möllmann Helge, Abdel-Wahab Mohamed, Ben Ali Walid, Mahoney Paul D, Ruge Hendrik, Wood David A, Bleiziffer Sabine, Ramlawi Basel, Gada Hemal, Petronio Anna Sonia, Resor Charles D, Merhi William, Garcia Del Blanco Bruno, Attizzani Guilherme F, Batchelor Wayne B, Gillam Linda D, Guerrero Mayra, Rogers Toby, Rovin Joshua D, Szerlip Molly, Whisenant Brian, Deeb G Michael, Grubb Kendra J, Padang Ratnasari, Fan Myra T, Althouse Andrew D, Tchétché Didier, SMART Trial Investigators. Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus.. The New England journal of medicine. 2024. DOI: 10.1056/nejmoa2312573.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.