Аннотация

BACKGROUND

There is ambiguity in the literature regarding the continuous suture technique (CST) for aortic valve replacement (AVR). At our center, there has been a gradual shift towards CST over the interrupted pledgeted technique (IPT). This study aims at comparing outcomes for both techniques.

METHODS

We performed a retrospective analysis of a single-center study of patients undergoing AVR between January 2011 and July 2020. Patients were divided into two groups: Continuous suture technique and interrupted pledget-reinforced sutures. The pre-operative and In-hospital clinical characteristics and echocardiographic hemodynamics (i.e. transvalvular gradients and paravalvular leakage) were compared between CST and IPT.

RESULTS

We compared 791 patients with CST to 568 patients with IPT (median age: 73 and 74 years, respectively, p = 0.02). In CST there were 35% concomitant procedure vs. 31% in IPT (p = 0.16). Early mortality was 3.2% in CST versus 4.8% in IPT (p = 0.15), and a second cross-clamp due to a paravalvular-leak in 0.5% vs. 1.2%, respectively (p = 0.22). The CST was not associated with new-onset conduction-blocks mandating pacemaker implants(OR 1.07, 95% CI 0.54-2.14; P = 0.85). The postoperative gradients on echocardiography were lower in CST compared to IPT, especially in smaller annuli (peak gradients: 15.7mmHg vs. 20.5mmHg, in valve size < 23 mm, p < 0.001).

CONCLUSIONS

The continuous suture technique was associated with lower postoperative gradients and shorter cross-clamp time compared to interrupted pledgeted technique. Differences in paravalvular leaks were non-significant, although slightly less in the continuous suture technique. There were no further differences in valve-related complications. Hence, continues suture technique is safe, with better hemodynamics compared to the interrupted pledgeted technique. This may be of clinical importance, especially in smaller size annular size.

Для цитирования: Arabkhani Bardia, Gonthier Sebastien, Lorenz Veronica, Deschamps Samuel, Jahanyar Jama, Boute Marin, Vancraeynest David, Mastrobuoni Stefano, Khoury Gebrine El, de Kerchove Laurent. Continuous or interrupted pledgeted suture technique in stented bioprosthetic aortic valve replacement: a comparison of in-hospital outcomes.. Journal of cardiothoracic surgery. 2024. DOI: 10.1186/s13019-024-02754-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.