Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.

Ventura A C, Böhnke M, Mojon D S

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter have served as the basis for adjusting readings pertaining to the latter, with the consequence that many patients have had to be reclassified. With a view to validating these pachymetric studies, the central corneal thickness was determined in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension, as well as that of normal subjects, using optical low coherence reflectometry, which is a new and more precise method than ultrasonic pachymetry.

METHODS

34 patients with normal tension glaucoma, 20 with primary open angle glaucoma, 13 with pseudoexfoliation glaucoma, and 12 with ocular hypertension, together with 21 control subjects, were included in this observational, concurrent case-control study. One eye per individual was randomly selected for investigation. IOP was measured by Goldmann applanation tonometry and central corneal thickness by optical low coherence reflectometry.

RESULTS

Central corneal thickness was significantly higher (p < or =0.001) in patients with ocular hypertension than in normal individuals or in subjects with either normal tension glaucoma, primary open angle glaucoma, or pseudoexfoliation glaucoma, there being no significant differences between the latter four groups. Patients with ocular hypertension were also significantly younger (p < or =0.003) than those within any of the three glaucomatous groups.

CONCLUSION

This study confirms that a significant number of patients with ocular hypertension have normal IOPs after the appropriate adjustments have been made for deviations from normal in their central corneal thickness. The accurate measurement of this latter parameter is important not only for individual patient care, in permitting more precise estimations of IOP, but also for clinical studies, in assuring a more reliable classification of subjects.

Для цитирования: Ventura A C, Böhnke M, Mojon D S. Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.. The British journal of ophthalmology. 2001. DOI: 10.1136/bjo.85.7.792.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.