m+Medelevator.RU
← Поиск публикаций
Anesthesiology · 2013

Pulmonary shunt is independent of decrease in cardiac output during unsupported spontaneous breathing in the pig.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vimlati Laszlo, Larsson Anders, Hedenstierna Goran, Lichtwarck-Aschoff Michael

Аннотация

BACKGROUND: During mechanical ventilation (MV), pulmonary shunt is cardiac output (CO) dependent; however, whether this relationship is valid during unsupported spontaneous breathing (SB) is unknown. The CO dependency of the calculated venous admixture was investigated, with both minor and major shunt, during unsupported SB, MV, and SB with continuous positive airway pressure (CPAP).

METHODS: In seven anesthetized supine piglets breathing 100% oxygen, unsupported SB, MV (with tidal volume and respiratory rate corresponding to SB), and 8 cm H2O CPAP (airway pressure corresponding to MV) were applied at random. Venous return and CO were reduced by partial balloon occlusion of the inferior vena cava. Measurements were repeated with the left main bronchus blocked, creating a nonrecruitable pulmonary shunt.

RESULTS: CO decreased from 4.2 l/min (95% CI, 3.9-4.5) to 2.5 l/min (95% CI, 2.2-2.7) with partially occluded venous return. Irrespective of whether shunt was minor or major, during unsupported SB, venous admixture was independent of CO (slope: minor shunt, 0.5; major shunt, 1.1% · min(-1) · l(-1)) and mixed venous oxygen tension. During both MV and CPAP, venous admixture was dependent on CO (slope MV: minor shunt, 1.9; major shunt, 3.5; CPAP: minor shunt, 1.3; major shunt, 2.9% · min(-1) · l(-1)) and mixed-venous oxygen tension (coefficient of determination 0.61-0.86 for all regressions).

CONCLUSIONS: In contrast to MV and CPAP, venous admixture was independent of CO during unsupported SB, and was unaffected by mixed-venous oxygen tension, casting doubt on the role of hypoxic pulmonary vasoconstriction in pulmonary blood flow redistribution during unsupported SB.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты