Automated dynamic motion correction improves repeatability and reproducibility of myocardial blood flow quantification with rubidium-82 PET imaging.

Choueiry Justen, Mistry Neel P, Beanlands Rob S B, deKemp Robert A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Patient motion reduces the accuracy of PET myocardial blood flow (MBF) measurements. This study evaluated the effect of automatic motion correction on test-retest repeatability and inter-observer variability in a clinically relevant population.

METHODS

Patients with known or suspected CAD underwent repeat rest 82Rb PET scans within minutes as part of their scheduled rest-stress perfusion study. Two trained observers evaluated the presence of heart motion in each scan. Global LV and per-vessel MBF were computed from the dynamic rest images before and after automatic motion correction. Test-retest and inter-observer variability were assessed using intra-class correlation and Bland-Altman analysis.

RESULTS

140 pairs of test-retest scans were included, with visual motion noted in 18%. Motion correction decreased the global MBF values by 3.5% (0.80 ± 0.24 vs 0.82 ± 0.25 mL⋅min-1⋅g-1; P < 0.001) suggesting that the blood input function was underestimated in cases with patient motion. Test-retest repeatability of global MBF improved by 9.7% (0.25 vs 0.28 mL⋅min-1⋅g-1; P < 0.001) and inter-observer repeatability was improved by 7.1% (0.073 vs 0.079 mL⋅min-1⋅g-1; P = 0.012). There was a marked impact on both test-retest repeatability as well as inter-observer repeatability in the LCX territory, with improvements of 16.5% (0.30 vs 0.36 mL⋅min-1⋅g-1; P < 0.0000) and 18.4% (0.13 vs 0.16 mL⋅min-1⋅g-1; P < 0.001), respectively.

CONCLUSION

Automatic motion correction improved test-retest repeatability and reduced differences between observers.

Для цитирования: Choueiry Justen, Mistry Neel P, Beanlands Rob S B, deKemp Robert A. Automated dynamic motion correction improves repeatability and reproducibility of myocardial blood flow quantification with rubidium-82 PET imaging.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2022. DOI: 10.1007/s12350-022-03134-x.