Rossi Tommaso, Querzoli Giorgio, Badas Maria Grazia, Angius Federico, Ripandelli Guido
Аннотация
PURPOSE: To investigate the behavior of silicone oil (SiO) at a steady equilibrium and during saccades in pseudophakic highly myopic eyes with posterior staphyloma with and without an encircling band and compare it to behavior in emmetropic eyes. The SiO-retina contact area and shear stress were calculated by computational fluid dynamics.
METHODS: A numerical model of an emmetropic eye and a myopic eye with and without scleral band underwent a saccade of 50°/0.137 s. The vitreous chamber surface was divided into superior and inferior 180° sectors: lens, pre-equator, post-equator, and macula. SiO-retina contact was evaluated as a function of fill percentages between 80% and 90% for standing, 45° upward tilt, and supine patients. Maximum and average shear stress were calculated.
RESULTS: Overall, SiO-retina contact ranged between 40% and 83%; fill percentage varied between 80% and 95%. Neither the encircling scleral band nor the staphyloma significantly affected the SiO-retina contact area, although the presence of a scleral band proved disadvantageous when gazing 45° upward. The inferior retina-SiO contact remained below 40% despite 95% SiO fill. The SS significantly increased at the scleral band indentation and decreased elsewhere. The staphyloma greatly reduced shear stress at the macula.
CONCLUSIONS: The presence of a myopic staphyloma reduces shear stress at the macula but does not alter SiO-retina contact significantly. The apposition of a 360° scleral band may reduce SiO-retina contact at least in some postures and increases the SS at the indentation.
TRANSLATIONAL RELEVANCE: Assessing SiO-retina contact when vitreous chamber geometry changes according to pathologic or iatrogenic modifications allows accurate prediction of real-life tamponade behavior and helps explain surgical outcomes.
METHODS: A numerical model of an emmetropic eye and a myopic eye with and without scleral band underwent a saccade of 50°/0.137 s. The vitreous chamber surface was divided into superior and inferior 180° sectors: lens, pre-equator, post-equator, and macula. SiO-retina contact was evaluated as a function of fill percentages between 80% and 90% for standing, 45° upward tilt, and supine patients. Maximum and average shear stress were calculated.
RESULTS: Overall, SiO-retina contact ranged between 40% and 83%; fill percentage varied between 80% and 95%. Neither the encircling scleral band nor the staphyloma significantly affected the SiO-retina contact area, although the presence of a scleral band proved disadvantageous when gazing 45° upward. The inferior retina-SiO contact remained below 40% despite 95% SiO fill. The SS significantly increased at the scleral band indentation and decreased elsewhere. The staphyloma greatly reduced shear stress at the macula.
CONCLUSIONS: The presence of a myopic staphyloma reduces shear stress at the macula but does not alter SiO-retina contact significantly. The apposition of a 360° scleral band may reduce SiO-retina contact at least in some postures and increases the SS at the indentation.
TRANSLATIONAL RELEVANCE: Assessing SiO-retina contact when vitreous chamber geometry changes according to pathologic or iatrogenic modifications allows accurate prediction of real-life tamponade behavior and helps explain surgical outcomes.