Optimized cleanup strategy for the determination of bisphenols in human serum with Na86(AlO2)86(SiO2)106 as sorbents: Molecular insights and critical factor evaluation.
Аннотация
BACKGROUND
Bisphenols, as ubiquitous environmental contaminants, pose significant public health concerns owing to their endocrine-disrupting properties. While liquid chromatography-tandem mass spectrometry is the gold standard for their trace-level quantification in biological matrices, its accuracy is fundamentally limited by substantial matrix effects. The development of separation techniques and analytical method for human biomonitoring will significantly advance human health risk assessment. The complexity of biological matrices and low concentrations of targets are the main challenges for human biomonitoring. Developing accessible and economic SPE sorbents suitable for the cleanup of serum is pivotal for conducting large-scale epidemiological and toxicological studies of BPs.
RESULTS
We present a cleanup protocol based on a 13X-type Na86(AlO2)86(SiO2)106 zeolite, and it achieved consistent and acceptable matrix effect suppression (63.3%-121%), outperforming commercial alternatives like C18 (15.0%-107%), HLB (4.5%-87.7%), and PEP-2 (8.9%-142%). Correlation analysis suggested that analyte recovery was significantly associated with logKow (P < 0.01) and positively correlated with estimated molecular volume. Combining the binding energy analysis, our finding suggested the role of shape selectivity and strong interaction (e.g. hydrogen bond interaction, electrostatic interaction) within the zeolite pores. The developed method was validated with bovine serum, demonstrating acceptable sensitivity (0.075-0.39 ng mL-1), precision (2.2%-18.0%), and accuracy (71.4%-124%). Its reliability for human biomonitoring was further evaluated by the good agreement with a reference method via Bland-Altman analysis.
SIGNIFICANCE: The zeolite-based SPE protocol demonstrates good selectivity and robustness, establishing it as a superior sample preparation technique for the biomonitoring of BPs in serum. It is feasible for the accurate assessment of the human internal exposure to BPs. In addition, our work identifies critical factors influencing extraction efficiency and molecular interactions via multiple regression analysis and molecular simulation, thereby providing a possible mechanistic insight.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.