MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-022-02328-z

Медицинская библиотека · International ophthalmology · 2022

One-year analysis of the refractive stability, axial elongation and related factors in a high myopia population after Implantable Collamer Lens implantation.

Chen Xun, Chen Zhi, Miao Huamao, Wang Xuanqi, Wang Xiaoying, Zhou Xingtao

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the refractive stability, axial length (AL) changes and their related factors in a high myopia population after Implantable Collamer Lens (ICL) implantation.

METHODS

This prospective study included 116 eyes of 116 patients divided into several groups based on the spherical equivalent refractive error (SE)-SE > - 6 D, - 12 ≤ SE < - 6 D and SE < - 12 D groups-and AL-AL < 28 mm and AL ≥ 28 mm groups. The uncorrected and corrected distance visual acuity, refraction, AL and intraocular pressure were followed for 1 year.

RESULTS

SE changed from - 11.53 ± 5.25 D preoperatively to - 0.33 ± 0.70 D at 1 week, and further changed to - 0.48 ± 0.77 D at 1 year after ICL implantation, with average progression being - 0.15 ± 0.37 D from 1 week to 1 year after surgery. AL changed from 27.95 ± 2.33 mm preoperatively to 27.98 ± 2.36 mm 1 year after surgery, with an average axial elongation of 0.03 ± 0.12 mm. The mean axial elongation rate was 0.05 mm/year in the SE < - 12 D group, being significantly faster than the other refractive groups (P < 0.05); it was 0.06 mm/year in the AL ≥ 28 mm group, being significantly faster than the AL < 28 mm group (P < 0.05).

CONCLUSION

Patients with high myopia and long AL showed a continuous myopic progression and axial elongation at an adult age one year after ICL surgery, especially in those with myopia higher than - 12.00 D and AL longer than 28.00 mm.

Для цитирования: Chen Xun, Chen Zhi, Miao Huamao, Wang Xuanqi, Wang Xiaoying, Zhou Xingtao. One-year analysis of the refractive stability, axial elongation and related factors in a high myopia population after Implantable Collamer Lens implantation.. International ophthalmology. 2022. DOI: 10.1007/s10792-022-02328-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.