MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjpt.2024.101085

Медицинская библиотека · Brazilian journal of physical therapy · 2024

Reliability and construct validity of the Craniocervical Flexion Test in patients with migraine.

Rodrigues Amanda, Carvalho Gabriela Ferreira, Florencio Lidiane Lima, Martins Jaqueline, Pinheiro-Araújo Carina Ferreira, Rosa Milena Dietrich Deitos, Dach Fabíola, Bevilaqua-Grossi Débora

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.

OBJECTIVES

To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.

METHODS

Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7-10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test - 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.

RESULTS

A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (p = 0.004, R = 0.35).

CONCLUSION

The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.

Для цитирования: Rodrigues Amanda, Carvalho Gabriela Ferreira, Florencio Lidiane Lima, Martins Jaqueline, Pinheiro-Araújo Carina Ferreira, Rosa Milena Dietrich Deitos, Dach Fabíola, Bevilaqua-Grossi Débora. Reliability and construct validity of the Craniocervical Flexion Test in patients with migraine.. Brazilian journal of physical therapy. 2024. DOI: 10.1016/j.bjpt.2024.101085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.