MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000004860

Медицинская библиотека · Medicine · 2016

A huge saccular aortic aneurysm compressing right coronary artery 7 years after aortic valve replacement due to bicuspid aortic valve insufficiency: A rare case report.

Park Sang Min, Jeong Haemin, Hong Kyung-Soon, Kim Christopher

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In a patient underwent aortic valve replacement (AVR) due to bicuspid aortic valve (BAV) insufficiency without marked dilation of ascending aorta, the development of delayed-typed aneurysmal complication of ascending aorta has been often reported because the dilated aorta tends to grow insidiously with age.

CASE SUMMARY: A 58-year-old man who underwent AVR with mechanical valve due to severe aortic regurgitation secondary to BAV 7 years previously presented with exertional chest discomfort for 1 year. An echocardiography showed a well-functioning mechanical aortic valve without any significant abnormal findings. Cardiac multidetector computed tomography (MDCT) revealed a huge saccular aortic root aneurysm (79.7 mm × 72.8 mm in size) compressing the proximal right coronary artery resulting in ∼90% eccentric diffuse luminal narrowing. The patient subsequently underwent open-heart surgery with resection of the ascending aortic aneurysmal sac and consecutive ascending aorta and hemi-arch replacement using a graft.

CONCLUSION

After successful AVR in the patient with BAV insufficiency and mildly dilated ascending aorta, a regular aortic imaging such as cardiac MDCT with aortography would be helpful to monitor the morphology and size of ascending aorta and related complications to guide future management.

Для цитирования: Park Sang Min, Jeong Haemin, Hong Kyung-Soon, Kim Christopher. A huge saccular aortic aneurysm compressing right coronary artery 7 years after aortic valve replacement due to bicuspid aortic valve insufficiency: A rare case report.. Medicine. 2016. DOI: 10.1097/md.0000000000004860.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.