MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.26576

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2016

Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis.

Landes Uri, Sagie Alexander, Kornowski Ran

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Sutureless aortic bioprostheses (SAB) are increasingly being used to provide shorter cross-clamp time. Valve-in-valve transcatheter aortic valve replacement (VIV-A) is shown to be effective and safe in the vast majority of patients with degenerated bioprosthetics, yet its' use in SAB failure is infrequent. We present a case of balloon-expandable VIV-A in an 80-year-old woman who suffered severe symptomatic aortic regurgitation in a failed Perceval S 21-mm valve. Computed tomography scan demonstrated a deformed valve. Our heart team favored a percutaneous VIV-A over reoperation due to the patients' high surgical risk. An Edwards-Sapien XT 23 mm was successfully deployed with excellent results. The patient remained asymptomatic following 6 months. As other bioprosthesis, some sutureless valves are condemned to structural valve degeneration. Because VIV-A is being established for managing degenerative bioprosthesis in high risk patients, it is cardinal to identify its role in novel degenerative sutureless valves. SAB were introduced to the clinical market only 5-7 years ago. The absence of sutures may theoretically impose risk for valve instability when adding a transcatheter sutureless valve inside the first one. Our successful experience was very reassuring. We report its feasibility because we believe it should provide support for further investigation on VIV-A within novel SAV. © 2016 Wiley Periodicals, Inc.

Для цитирования: Landes Uri, Sagie Alexander, Kornowski Ran. Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.26576.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.