Аннотация

BACKGROUND

Aortic insufficiency (AI) is a significant long-term complication of continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate its impact on clinical outcomes and mortality in CF-LVAD recipients.

METHODS

We retrospectively analyzed 237 patients implanted with HeartMate II CF-LVADs at our institution from June 2005 through June 2013. We evaluated recipients' baseline characteristics and annual echocardiograms, grading AI severity as either none, trace, mild, moderate or severe. Only moderate or severe AI was considered clinically significant. Recipients who underwent concomitant aortic valve surgery or who had undergone previous prosthetic aortic valve implantation were excluded.

RESULTS

Moderate or severe AI occurred in 32 (15.2%) patients. Risk factors that significantly affected the development of AI included older age at the time of implantation, female gender, longer duration of LVAD support and destination therapy designation. Freedom from moderate or severe AI was 94%, 76% and 65% of patients at 1, 3 and 5 years, respectively. Overall cohort survival based on Kaplan-Meier analysis was 78%, 59% and 42% at 1, 3 and 5 years, respectively. There was no difference in survival between recipients who developed significant AI and those who did not (log-rank test, p = 0.73).

CONCLUSIONS

In this large, single-institution study, the overall rate of AI was low, but increased in frequency with longer duration of LVAD support. Although AI development remains a concern for patients on long-term CF-LVAD support, AI development does not appear to impact long-term mortality.

Для цитирования: Holley Christopher T, Fitzpatrick Megan, Roy Samit S, Alraies M Chadi, Cogswell Rebecca, Souslian Laura, Eckman Peter, John Ranjit. Aortic insufficiency in continuous-flow left ventricular assist device support patients is common but does not impact long-term mortality.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2016. DOI: 10.1016/j.healun.2016.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.