MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0151247

Медицинская библиотека · PloS one · 2016

Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience.

Wöhrle Jochen, Gonska Birgid, Rodewald Christoph, Seeger Julia, Scharnbeck Dominik, Rottbauer Wolfgang

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: The third generation Edwards Sapien 3 (Edwards Lifesciences Inc., Irvine, California) system was optimized to reduce residual aortic regurgitation and vascular complications.

METHODS AND

RESULTS

235 patients with severe symptomatic aortic stenosis were prospectively enrolled. Transcatheter aortic valve implantations (TAVI) were performed without general anesthesia by transfemoral approach. Patients were followed for 30 days. Patients received 23mm (N = 77), 26mm (N = 91) or 29mm (N = 67) valve based on pre-procedural 256 multislice computer tomography. Mean oversizing did not differ between the 3 valves. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation and regurgitation index did not differ between groups. There was no switch to general anesthesia or conversion to surgery. Rate of major vascular complication was 3.0% with no difference between valve and delivery sheath sizes. Within 30 days rates of all cause mortality (2.6%) and stroke (2.1%) were low.

CONCLUSIONS

In patients with severe aortic stenosis transfemoral TAVI with the Edwards Sapien 3 valve without general anesthesia was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complication, mortality and stroke within 30 days with no difference between the 3 valve sizes.

TRIAL REGISTRATION: ClinicalTrials.gov NCT02162069.

Для цитирования: Wöhrle Jochen, Gonska Birgid, Rodewald Christoph, Seeger Julia, Scharnbeck Dominik, Rottbauer Wolfgang. Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience.. PloS one. 2016. DOI: 10.1371/journal.pone.0151247.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.