Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation.

Carey Paul J, Leccisotti Antonio, McGilligan Victoria E, Goodall Ed A, Moore C B Tara

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the validity of an internal optical path difference map of a refractive power/corneal analyzer system in determining the alignment of toric intraocular lenses (IOLs).

SETTINGS: Private practices, Spring Hill, Brisbane, and Chermside, Australia.

METHODS

This retrospective study comprised patients with more than 1.5 diopters of preexisting corneal astigmatism who had phacoemulsification and AcrySof toric IOL implantation. Preoperatively, the surgical eye was marked at the slitlamp microscope using a 4-point technique. The desired IOL orientation was marked with a Mendez marker based on the steep corneal axis. The toric IOL axis was measured 3 weeks postoperatively by rotating the slitlamp beam to align with the IOL axis indicator marks and using the Internal OPD Map on the Nidek OPD-Scan system. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, residual refractive sphere, and residual keratometric and refractive cylinders were also measured at 3 weeks.

RESULTS

Postoperatively, the mean UDVA was 0.17 logMAR +/- 0.18 (SD) and the mean CDVA, -0.01 +/- 0.12 logMAR; 88.2% of eyes had a UDVA of 0.3 or better, and no eye lost lines of visual acuity. There was an 82.33% reduction in defocus equivalent and a 64.62% reduction in refractive cylinder. The mean IOL misalignment measured by slitlamp was 2.55 +/- 2.76 degrees and by the internal map, 2.65 +/- 1.98 degrees. The correlation between the 2 methods was highly significant (r = 0.99, P<.001).

CONCLUSIONS

Both refractive power/corneal analyzer system and slitlamp observation were reliable and predictable methods of assessing IOL alignment. The 4-point preoperative marking technique yielded clinically acceptable, accurate toric IOL alignment.

Для цитирования: Carey Paul J, Leccisotti Antonio, McGilligan Victoria E, Goodall Ed A, Moore C B Tara. Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2009.08.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.