MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jfo.2009.06.001

Медицинская библиотека · Journal francais d'ophtalmologie · 2009

[Arcuate keratotomy for postkeratoplasty astigmatism by femtosecond laser].

Hoffart L, Proust H, Matonti F, Baeteman C, De Langlade P G, Conrath J, Ridings B

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Evaluation of the effectiveness of arcuate keratotomy performed with femtosecond laser for correction of postkeratoplasty astigmatism.

METHODS

This retrospective clinical study included 11 eyes. All cases underwent arcuate keratotomy using femtosecond laser. Outcome measures included visual acuity and endothelial cell density as well as refractive, keratometric, and topographic astigmatism. The incision depth was also evaluated by OCT-3.

RESULTS

With a mean follow-up of 7.4+/-6.7 months, uncorrected visual acuity was not modified and the mean best corrected visual acuity significantly improved from 1.68+/-1.59 lines (p=0.007). The mean preoperative refractive cylinder was 5.18+/-1.15D, decreasing to 3.41+/-1.93D (p=0.045) after laser-arcuate keratotomy. The reduction of preoperative keratometric (7.79+/-3.69D) and topographic (7.98+/-2.41D) astigmatism was higher, with a decrease to 4.81+/-2.52D (p=0.021) and 4.36+/-2.59D (p=0.005) postoperatively. Endothelial cell density was not modified after surgery. The difference between achieved and planned incision depth was -10.7+/-63.5mum. All cases were uncomplicated.

DISCUSSION: Arcuate keratotomies performed with the femtosecond laser were effective in reducing postkeratoplasty astigmatism and has a number of advantages over conventional techniques. However, efficacy could be improved by a more accurate nomogram.

CONCLUSION

Arcuate keratotomy performed with femtosecond laser is a relatively easy, safe, and effective means of treating postkeratoplasty astigmatism. Given our small sample, much larger series are needed to provide more confident estimates of astigmatism reduction proportions and to adjust correction parameters.

Для цитирования: Hoffart L, Proust H, Matonti F, Baeteman C, De Langlade P G, Conrath J, Ridings B. [Arcuate keratotomy for postkeratoplasty astigmatism by femtosecond laser].. Journal francais d'ophtalmologie. 2009. DOI: 10.1016/j.jfo.2009.06.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.