Aspheric profile versus wavefront-guided ablation photorefractive keratectomy for the correction of myopia using the Allegretto Eye Q.

Ghoreishi Seyyed Mohammad, Naderibeni Afsaneh, Peyman Alireza, Rismanchian Akram, Eslami Fatemeh

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the results of photorefractive keratectomy (PRK) with Q-factor customized aspheric ablation and wavefront-guided customized ablation for correction of myopia compound with astigmatism.

METHODS

Fifty-six patients were enrolled in this prospective controlled study. In each patient, one eye was randomly assigned for treatment with the Q-factor customized PRK (custom-Q study group) and the other eye treated with wavefront-guided customized PRK. Preoperative and 3-month postoperative manifest refraction, contrast sensitivity, visual acuity, aberrometry, and asphericity of the cornea were compared between the two groups. All eyes were treated with the Wavelight Eye-Q 400 Hz excimer laser in a single refractive surgery center by a single surgeon.

RESULTS

Uncorrected visual acuity (UCVA) improved to 20/20 or more and 20/25 or more in 34 eyes (60.7%) and 56 eyes (100%), respectively, in the wavefront-guided ablation group and in 36 eyes (64.2%) and 54 eyes (96.4%) in the custom-Q ablation group. All eyes had UCVA of 20/40 or better. A total of 54 eyes (96.4%) in the wavefront-guided ablation group and 56 (100%) in the custom-Q ablation group had spherical equivalent (SE) within -/+0.5 D. One eye in each group (2%) lost >or=2 lines of best-corrected visual acuity (BCVA). High order root mean square (RMS) in the wavefront-guided group was 0.3630-/+0.13 mum preoperatively and 0.427-/+0.17 at 3 months (p=0.2). In the custom-Q ablation group it was 0.329-/+0.092 preoperatively and 0.4730-/+0.181 at 3 months after PRK (p=0.08).

CONCLUSIONS

Regarding safety and refractive efficacy, custom-Q ablation profiles were clinically equivalent to wavefront-guided profiles in corrections of myopia up to -6.00 D and astigmatism up to 2.50 D.

Для цитирования: Ghoreishi Seyyed Mohammad, Naderibeni Afsaneh, Peyman Alireza, Rismanchian Akram, Eslami Fatemeh. Aspheric profile versus wavefront-guided ablation photorefractive keratectomy for the correction of myopia using the Allegretto Eye Q.. European journal of ophthalmology. 2009. DOI: 10.1177/112067210901900405.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.