Knotless Suture Anchors Display Favorable Elongation but an Inferior Ultimate Failure Load Versus Titanium Suture Anchors and All-Suture Anchors: A Biomechanical Comparison in a Porcine Model.
Аннотация
BACKGROUND
Several types of suture anchors, which differ in their working principles, are available for fixation of ligamentous structures in knee surgery. How the choice of a suture anchor type influences the biomechanical stability of ligament fixation is largely unknown.
PURPOSE: To compare the biomechanical properties of different suture anchor designs regarding primary stability for tendon fixation and repair in medial collateral ligament (MCL) surgery.
STUDY
DESIGN
Controlled laboratory study.
METHODS
The primary stability of MCL fixation was assessed in a porcine model utilizing 1 of 3 suture anchor types: a 5.5-mm titanium suture anchor (TSA), a 2.8-mm all-suture anchor (ASA), or a 5.5-mm polyether ether ketone knotless suture anchor (KLSA). Primary stability was assessed using a uniaxial material testing machine. Cyclic loading at 50 N and 100 N was applied for 500 cycles each, followed by a load-to-failure test.
RESULTS
After 500 cycles at 50 N, the KLSA (2.4 ± 0.3 mm) showed significantly (P < .05) reduced elongation in comparison to the TSA (4.0 ± 0.9 mm) and ASA (3.6 ± 0.7 mm), and after 500 cycles at 100 N, the KLSA (6.5 ± 1.4 mm) again showed significantly (P < .05) reduced elongation in comparison to the TSA (11.0 ± 2.2 mm) and ASA (12.0 ± 3.6 mm). However, the KLSA (213 ± 27 N) showed a significantly (P < .05) inferior ultimate failure load in comparison to the TSA (300 ± 20 N) and ASA (348 ± 23 N). In comparison to the TSA (113.0 ± 11.0 N/mm) and ASA (113.6 ± 14.4 N/mm), the KLSA (150.7 ± 11.6 N/mm) displayed the highest stiffness (P < .05). No significant differences were observed regarding yield load.
CONCLUSION
KLSAs displayed significantly reduced elongation, at the cost of a reduced ultimate failure load, in comparison to TSAs and ASAs.
CLINICAL RELEVANCE: Surgeons should be aware that differences exist between different suture anchor types regarding their biomechanical stability. KLSAs may be favorable for fixation of peripheral ligaments in knee surgery.