MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0161-6420(94)38029-8

Медицинская библиотека · Ophthalmology · 1994

Clinical and subclinical ophthalmic findings with retinol deficiency.

Newman N J, Capone A, Leeper H F, O'Day D G, Mandell B, Lambert S R, Thoft R A

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients at risk for retinol deficiency in developed countries include those with hepatic dysfunction and malabsorption states. Symptoms of retinol deficiency may go unrecognized or unreported.

METHODS

The authors describe 15 patients with hepatic dysfunction, two of whom had procedures that would predispose to malabsorption and were ophthalmologically symptomatic of retinol depletion. The other 13 patients were ophthalmologically asymptomatic liver transplant candidates examined prospectively for subclinical evidence of retinol deficiency. Combined laboratory analysis, Schirmer's testing, conjunctival impression cytology, and electroretinography were performed.

RESULTS

Twelve of 15 patients had serum retinol levels below the lower limit of normal. Aqueous tear production was reduced in 7 of 14 patients. Abnormal conjunctival morphology was noted in 6 of 12 patients. Electroretinograms were abnormal in the two patients who were visually symptomatic and in seven of nine patients who were ophthalmologically asymptomatic.

CONCLUSION

Subclinical, physiologically significant retinol deficiency may be a frequent and unrecognized problem among patients with hepatic dysfunction.

Для цитирования: Newman N J, Capone A, Leeper H F, O'Day D G, Mandell B, Lambert S R, Thoft R A. Clinical and subclinical ophthalmic findings with retinol deficiency.. Ophthalmology. 1994. DOI: 10.1016/s0161-6420(94)38029-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.