MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1054/jhsb.1999.0240

Медицинская библиотека · Journal of hand surgery (Edinburgh, Scotland) · 1999

The effect of the additional use of grommets in silicone implant arthroplasty of the metacarpophalangeal joints.

Schmidt K, Willburger R, Ossowski A, Miehlke R K

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

After silicone arthroplasty of the metacarpophalangeal (MP) joint there is increasing osteolysis, subsidence and fracture of the implants in the longer postoperative term. In 44 patients with rheumatoid arthritis (54 hands) 151 arthroplasties of the metacarpophalangeal joint were assessed at a mean of 3.9 years postoperatively. In 57 arthroplasties titanium protectors (grommets) were used. There were no significant differences in the clinical outcomes with respect to swelling, correction of ulnar deviation, range of active movement and grip strength. The additional use of grommets in MP joint arthroplasty slightly reduced reactive osteolysis, protected the spacers from breakage and slightly reduced the amount of pain with only a few additional complications in the midterm follow-up.

Для цитирования: Schmidt K, Willburger R, Ossowski A, Miehlke R K. The effect of the additional use of grommets in silicone implant arthroplasty of the metacarpophalangeal joints.. Journal of hand surgery (Edinburgh, Scotland). 1999. DOI: 10.1054/jhsb.1999.0240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.