Circulation. Cardiovascular quality and outcomes · 2022

Time-of-Day and Clinical Outcomes After Surgical or Transcatheter Aortic Valve Replacement: Insights From the PARTNER Trials.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vincent Flavien, Thourani Vinod H, Ternacle Julien, Redfors Bjorn, Cohen David J, Hahn Rebecca T, Li Ditian, Crowley Aaron, Webb John G, Mack Michael J, Kapadia Samir, Russo Mark, Smith Craig R, Alu Maria C, Leon Martin B, Pibarot Philippe

Аннотация

BACKGROUND: Circadian rhythms may influence myocardial tolerance to ischemia-reperfusion phenomena occurring during cardiac procedures. While conflicting results exist on the effect of time-of-day on surgical aortic valve replacement (SAVR), afternoon procedures could be associated with a reduced risk of death, rehospitalization or periprocedural myocardial infarction, compared with morning procedures. We examined the impact of procedure time-of-day on outcomes after transcatheter aortic valve replacement (TAVR) or SAVR.

METHODS: We analyzed patients at intermediate- or high-surgical risk who underwent elective TAVR (n=4457) or SAVR (n=1129) in the PARTNER (Placement of Aortic Transcatheter Valve) 1 and 2 trials and registries according to time-of-day (morning versus afternoon) using the Kaplan-Meier event rates and multivariable Cox proportional hazards regression models. Sensitivity analysis was conducted using 1:1 propensity-score matching. The primary end point was all-cause death or rehospitalization at 2 years.

RESULTS: At 2 years, no difference was observed between patients operated in the morning versus the afternoon within the SAVR (32.3% versus 30.6%, adjusted hazard ratio, 1.08 [95% CI, 0.82-1.41], P=0.58) and TAVR cohorts (35.7% versus 35.4%, adjusted hazard ratio, 1.01 [95% CI, 0.89-1.14], P=0.86) with regards to the primary end point. Rates of periprocedural myocardial infarction were low and similar between morning and afternoon in SAVR (1.6% versus 1.0%, P=0.51) and TAVR (0.4% versus 0.4%, P=0.86), as were all other clinical end points. Similar results were observed in propensity-score matched analysis.

CONCLUSIONS: Procedure time-of-day was not associated with clinical outcomes after TAVR or SAVR. Registration: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT00530894, NCT01314313, NCT03222141, and NCT03222128.