Majmundar Monil, Doshi Rajkumar, Kumar Ashish, Johnston Douglas, Brockett James, Kanaa'N Anmar, Lahorra Joseph A, Svensson Lars G, Krishnaswamy Amar, Reed Grant W, Puri Rishi, Kapadia Samir R, Kalra Ankur
Аннотация
BACKGROUND: Limited data are available regarding clinical outcomes of valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) following the United States Food and Drug Administration approval of ViV TAVI in 2015.
AIMS: The aim of this study was to evaluate in-hospital, 30-day, and 6-month outcomes of ViV TAVI versus repeat surgical aortic valve replacement (SAVR) in patients with a failed aortic bioprosthetic valve.
METHODS: This retrospective cohort study identified patients who underwent ViV TAVI or repeat SAVR utilising the Nationwide Readmission Database from 2016 to 2018. Primary outcomes were all-cause readmission (at 30 days and 6 months) and in-hospital death. Secondary outcomes were in-hospital stroke, pacemaker implantation, 30-day/6-month major adverse cardiac events (MACE), and mortality during readmission. Propensity score-matching (inverse probability of treatment weighting) analyses were implemented.
RESULTS: Out of 6,769 procedures performed, 3,724 (55%) patients underwent ViV TAVI, and 3,045 (45%) underwent repeat SAVR. ViV TAVI was associated with lower in-hospital all-cause mortality (odds ratio [OR] 0.42, 95% confidence interval [CI]: 0.20-0.90, p=0.026) and a higher rate of 30-day (hazard ratio [HR] 1.46, 95% CI: 1.13-1.90, p=0.004) and 6-month all-cause readmission (HR 1.54, 95% CI: 1.14-2.10, p=0.006) compared with repeat SAVR. All secondary outcomes were comparable between the two groups.
CONCLUSIONS: ViV TAVI was associated with lower in-hospital mortality but higher 30-day and 6-month all-cause readmission. However, there was no difference in risk of in-hospital stroke, post-procedure pacemaker implantation, MACE, and mortality during 30-day and 6-month readmission compared with repeat SAVR, suggesting that ViV TAVI can be performed safely in carefully selected patients.
AIMS: The aim of this study was to evaluate in-hospital, 30-day, and 6-month outcomes of ViV TAVI versus repeat surgical aortic valve replacement (SAVR) in patients with a failed aortic bioprosthetic valve.
METHODS: This retrospective cohort study identified patients who underwent ViV TAVI or repeat SAVR utilising the Nationwide Readmission Database from 2016 to 2018. Primary outcomes were all-cause readmission (at 30 days and 6 months) and in-hospital death. Secondary outcomes were in-hospital stroke, pacemaker implantation, 30-day/6-month major adverse cardiac events (MACE), and mortality during readmission. Propensity score-matching (inverse probability of treatment weighting) analyses were implemented.
RESULTS: Out of 6,769 procedures performed, 3,724 (55%) patients underwent ViV TAVI, and 3,045 (45%) underwent repeat SAVR. ViV TAVI was associated with lower in-hospital all-cause mortality (odds ratio [OR] 0.42, 95% confidence interval [CI]: 0.20-0.90, p=0.026) and a higher rate of 30-day (hazard ratio [HR] 1.46, 95% CI: 1.13-1.90, p=0.004) and 6-month all-cause readmission (HR 1.54, 95% CI: 1.14-2.10, p=0.006) compared with repeat SAVR. All secondary outcomes were comparable between the two groups.
CONCLUSIONS: ViV TAVI was associated with lower in-hospital mortality but higher 30-day and 6-month all-cause readmission. However, there was no difference in risk of in-hospital stroke, post-procedure pacemaker implantation, MACE, and mortality during 30-day and 6-month readmission compared with repeat SAVR, suggesting that ViV TAVI can be performed safely in carefully selected patients.