m+Medelevator.RU
← Поиск публикаций
Cardiovascular revascularization medicine : including molecular interventions · 2021

Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients: Meta-Analysis.

СтатьяМетаанализНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Medranda Giorgio A, Rogers Toby, Doros Gheorghe, Zhang Cheng, Case Brian C, Yerasi Charan, Shults Christian C, Waksman Ron

Аннотация

BACKGROUND: Most pivotal transcatheter aortic valve replacement (TAVR) trials have excluded patients with bicuspid aortic stenosis (AS). This study compared TAVR in low-risk patients with bicuspid AS to those with tricuspid AS, incorporating data from prospective trials.

METHODS: We selected prospective US low-risk TAVR trials containing a bicuspid arm for this meta-analysis, examining outcomes at 30 days. Study results were pooled using a hierarchical Bayesian random-effects model.

RESULTS: Included were 3 Food and Drug Administration (FDA)-approved investigational device exemption (IDE) trials that enrolled a total of 1810 low-risk patients with symptomatic severe AS for TAVR. We compared 380 bicuspid patients with 1430 tricuspid patients. Event rates at 30 days overall were low, with similar mortality (odds ratio [OR], 0.38; 95% credible interval [CrI]: 0.08, 1.78; I2, 0%), non-disabling stroke (OR, 0.45; 95% CrI: 0.15, 1.07; I2, 9%), and permanent pacemaker implantation (OR, 0.86; 95% CrI: 0.41, 1.47; I2, 59%). There were statistically significant differences in disabling stroke (OR, 0.16; 95% CrI: 0.01, 0.90; I2, NA) and coronary obstruction (OR, 0.21; 95% CrI: 0.05, 0.91) that disappeared after sensitivity analysis by adding a single event to the tricuspid arm. Hemodynamics were similar at 30 days.

CONCLUSIONS: Preliminary data from the FDA-approved IDE trials of low-risk patients with bicuspid AS undergoing TAVR demonstrated 30-day outcomes comparable to low-risk tricuspid patients, except for a trend toward higher stroke in bicuspid patients. Randomized trials are warranted to reassure the safety and long-term outcome of TAVR in patients with severe bicuspid AS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты