DOI 10.1186/s12872-021-02135-x
Combined evaluation of coronary artery disease and high-sensitivity cardiac troponin T for prediction of adverse events in patients with hypertrophic cardiomyopathy.
Аннотация
BACKGROUND
This study was performed to investigate the clinical significance of combined evaluation of both coronary artery disease (CAD) and high-sensitivity cardiac troponin T (hs-cTnT) for prediction of major adverse cardiovascular events (MACEs) in patients with hypertrophic cardiomyopathy (HCM).
METHODS
We performed clinical evaluations, including coronary artery imaging and hs-cTnT measurement, in 162 patients with HCM.
RESULTS
The patients were followed up for a median period of 3.7 years (interquartile range 2.4-5.6 years; total of 632.3 person-years [PYs]), during which time MACEs occurred in 24 (14.8%) patients. The incidence of MACEs was 6.4 and 2.7 per 100 PYs for patients with CAD and normal coronary arteries, respectively; similarly, the incidence was 5.8 and 2.1 per 100 PYs in patients with an elevated hs-cTnT concentration (> 14.0 ng/L) and a normal hs-cTnT concentration, respectively. The multivariate analysis suggested that CAD and an elevated hs-cTnT concentration tended to be positively associated with MACEs. When the groups were allocated according to these two markers, the patients were divided into four groups, which further improved the predictive values. The incidence of MACEs was 10.4 per 100 PYs in the CAD and elevated hs-cTnT group, which was much higher than the incidence in all other groups (range, 2.0-3.5 per 100 PYs). With the normal coronary arteries and normal hs-cTnT group serving as a reference, the adjusted hazard ratio was 5.0 (95% confidence interval 1.0-23.8; P = 0.046) for the CAD and elevated hs-cTnT group. In addition, the subgroup analysis showed similar findings among the patients without severe CAD.
CONCLUSIONS
In patients with HCM, combined evaluation of both CAD and hs-cTnT might facilitate more reliable prediction of MACEs than evaluation of a single marker. These may serve as clinically useful markers to guide risk management.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.