European journal of nuclear medicine and molecular imaging · 2020
FDG-PET/CT imaging during the Covid-19 emergency: a southern Italian perspective.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Maurea Simone, Mainolfi Ciro Gabriele, Bombace Claudia, Annunziata Alessandra, Attanasio Ludovica, Petretta Mario, Del Vecchio Silvana, Cuocolo Alberto
Аннотация
PURPOSE: To assess the impact of the Covid-19 pandemic on FDG-PET/CT work volume and to evaluate the occurrence of abnormal imaging findings suspicious or potentially diagnostic for interstitial pneumonia by Covid-19 infection in south Italy.
METHODS: We retrospectively reviewed the number and the findings of FDG-PET/CT studies acquired between February and April 2020 during the Covid-19 pandemic at the University of Napoli Federico II. The number and the findings of FDG-PET/CT studies acquired in the corresponding period of 2019 were also assessed for direct comparison.
RESULTS: The number of FDG-PET/CT studies performed during the pandemic (n = 299) and in the corresponding period of 2019 (n = 335) were comparable. The percentage of abnormal FDG-PET/CT findings, suspicious for interstitial pneumonia by Covid-19 infection, was significantly higher during the pandemic (9%) compared with that found in the corresponding period of 2019 (4%) (χ2 5.45, P = 0.02). No significant differences were observed in the distribution of Covid-19 reporting and data system (CO-RADS) classification and in the maximum standardized uptake value between the pandemic (2.6 ± 2.2) and the corresponding period of 2019 (3.2 ± 1.4). Of note, patients with abnormal imaging findings during the pandemic time had clinical data and/or laboratory tests negative for Covid-19 infection.
CONCLUSION: Despite the restrictive medical measures for the emergency, the number of FDG-PET/CT studies was unchanged during the pandemic compared with the previous year. Our findings also indicate that Covid-19 infection was contained in our series of patients from southern Italy.
METHODS: We retrospectively reviewed the number and the findings of FDG-PET/CT studies acquired between February and April 2020 during the Covid-19 pandemic at the University of Napoli Federico II. The number and the findings of FDG-PET/CT studies acquired in the corresponding period of 2019 were also assessed for direct comparison.
RESULTS: The number of FDG-PET/CT studies performed during the pandemic (n = 299) and in the corresponding period of 2019 (n = 335) were comparable. The percentage of abnormal FDG-PET/CT findings, suspicious for interstitial pneumonia by Covid-19 infection, was significantly higher during the pandemic (9%) compared with that found in the corresponding period of 2019 (4%) (χ2 5.45, P = 0.02). No significant differences were observed in the distribution of Covid-19 reporting and data system (CO-RADS) classification and in the maximum standardized uptake value between the pandemic (2.6 ± 2.2) and the corresponding period of 2019 (3.2 ± 1.4). Of note, patients with abnormal imaging findings during the pandemic time had clinical data and/or laboratory tests negative for Covid-19 infection.
CONCLUSION: Despite the restrictive medical measures for the emergency, the number of FDG-PET/CT studies was unchanged during the pandemic compared with the previous year. Our findings also indicate that Covid-19 infection was contained in our series of patients from southern Italy.