MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2019.01.063

Медицинская библиотека · World neurosurgery · 2019

A Phantom Menace to Medical Personnel During Endovascular Treatment of Cerebral Aneurysms: Real-Time Measurement of Radiation Exposure During Procedures.

Kim Tackeun, Kwon O-Ki, Ban Seung Pil, Kim Young Deok, Won Yu Deok

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The number of endovascular treatment procedures performed for cerebral aneurysms has markedly increased. However, little is known about the annual effective radiation dose to medical staff in neurointervention fields. We performed a retrospective observational study to investigate the real-time radiation dose to surgeons, nurses, anesthesiologists, and radiologic technologists during endovascular treatment of intracranial aneurysms.

METHODS

We measured the real-time radiation doses for 2 weeks using standard and reinforced protection, during which 28 procedures were performed, including 23 coil embolizations for unruptured intracranial aneurysms. Four procedures were excluded because of an inadequately equipped sensor, which resulted in inappropriate data collection. The procedure time was defined from intubation to extubation. Five RaySafe i2 detectors were installed at the chest level of the operator, attending nurse, radiologic technologist, and anesthesiologist and just inside the front door of the hybrid operating room.

RESULTS

The median doses per session with standard protection to the operator, attending nurse, anesthesiologist, and radiologic technologist were 11.16, 2.60, 4.76, and 1.93 μSv, respectively. The dose to the operator, attending nurse, and anesthesiologist had decreased to 6.63, 0.39, and 1.52 μSv under reinforced protection, respectively. However, the session dose for the radiologic technologist had increased to 3.12 μSv.

CONCLUSIONS

We confirmed the differences in the amount of radiation exposure for different roles. An additional lead screen, which provided more effective protection on the operator side, was proved effective for attenuating radiation exposure during endovascular treatment. All personnel involved in the hybrid operating room were exposed to acceptable effective doses.

Для цитирования: Kim Tackeun, Kwon O-Ki, Ban Seung Pil, Kim Young Deok, Won Yu Deok. A Phantom Menace to Medical Personnel During Endovascular Treatment of Cerebral Aneurysms: Real-Time Measurement of Radiation Exposure During Procedures.. World neurosurgery. 2019. DOI: 10.1016/j.wneu.2019.01.063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.