m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2013

Adenosine testing in atrial flutter ablation: unmasking of dormant conduction across the cavotricuspid isthmus and risk of recurrence.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Morales Gustavo X, Macle Laurent, Khairy Paul, Charnigo Richard, Davidson Evan, Thal Sergio, Ching C K, Lellouche Nicolas, Whitbeck Matthew, Delisle Brian, Thompson Jenks, Di Biase Luigi, Natale Andrea, Nattel Stanley, Elayi Claude S

Аннотация

BACKGROUND: Adenosine-induced hyperpolarization may identify pulmonary veins at risk of reconnection following electrical isolation for atrial fibrillation. The potential role of adenosine testing in other arrhythmic substrates, such as cavotricuspid isthmus (CTI)-dependent atrial flutter, remains unclear. We assessed whether dormant conduction across the CTI may be revealed by adenosine after ablation-induced bidirectional block, and its association with recurrent flutter.

METHODS AND RESULTS: Patients undergoing catheter ablation for CTI-dependent flutter were prospectively studied. After confirming bidirectional block across the CTI by standard pacing maneuvers, adenosine (≥ 12 mg IV) was administered to assess resumption of conduction, followed by isoproterenol (ISP) bolus. Further CTI ablation was performed for persistent (but not transient) resumption of conduction. Bidirectional block across the CTI was achieved in all 81 patients (63 males), age 61.2 ± 11.0 years. The trans-CTI time increased from 71.9 ± 18.1 milliseconds preablation to 166.2 ± 26.4 milliseconds postablation. Adenosine elicited resumption of conduction across the CTI in 7 patients (8.6%), 2 of whom had transient recovery. No additional patient with dormant conduction was identified by ISP. Over a follow-up of 11.8 ± 8.0 months, atrial flutter recurred in 4 (4.9%) patients, 3/7(42.9%) with a positive adenosine challenge versus 1/74 (1.3%) with a negative response, P = 0.0016 (relative risk 31.7).

CONCLUSION: Adenosine challenge following atrial flutter ablation provoked transient or persistent resumption of conduction across the CTI in almost 9% of patients and identified a subgroup at higher risk of flutter recurrence. It remains to be determined whether additional ablation guided by adenosine testing during the index procedure may further improve procedural outcomes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты