MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/tsaco-2018-000184

Медицинская библиотека · Trauma surgery & acute care open · 2018

Experience with uncrossmatched blood refrigerator in emergency department.

Harris Charles T, Totten Michael, Davenport Daniel, Ye Zhan, O'Brien Julie, Williams Dennis, Bernard Andrew, Boral Leonard

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Uncrossmatched packed red blood cell (PRBC) transfusion is fundamental in resuscitation of hemorrhagic shock. Ready availability of uncrossmatched blood can be achieved by storing uncrossmatched blood in a blood bank refrigerator in the emergency department (ED), but could theoretically lead to inappropriate uncrossmatched use.

METHODS

This retrospective study was performed at a level I trauma center from January 2013 to March 2014. Possibly inappropriate transfusion was defined as patients who received at least one unit of blood from the ED refrigerator and no more than two units of PRBC in the first 24 hours. Deaths within the first 24 hours were excluded. Patients who received blood from the ED refrigerator who received ≤2 units total in 24 hours were compared with those who received >2 units.

RESULTS

158 adults received blood from the ED refrigerator. 140 (88.6%) were trauma patients. 37 (23.4%) received massive transfusion (MT). 42 (26.6%) deaths were excluded. 29 patients received ≤2 units and 87 received >2 units in the first 24  hours. The ≤2 units group had a higher systolic blood pressure (116  mm Hg vs. 102  mm Hg, p=0.042), lower base deficit (6.4 mEq/L vs. 9.4 mEq/L, p=0.032), higher hematocrit (34% vs. 30%, p=0.024), lower rate of MT protocol activation (27.6% vs. 58.6%, p=0.005), and lower rates of transfusion of fresh frozen plasma (17.2% vs. 54.0%, p=0.001) and platelets (13.8% vs. 39.1%, p=0.012). Appropriately transfused patients were more likely to have evidence of shock with active, non-compressible hemorrhage. Potentially inappropriate uses were more likely in patients either without evidence of hemorrhage or without signs of shock.

DISCUSSION: Storing uncrossmatched blood in the ED is an effective way to get PRBCs transfused quickly in hemorrhaging patients and is associated with a low rate of unnecessary uncrossmatched transfusion. Provider education and good clinical judgment are imperative to prevent unnecessary use.

LEVEL OF EVIDENCE: Level III, therapeutic.

Для цитирования: Harris Charles T, Totten Michael, Davenport Daniel, Ye Zhan, O'Brien Julie, Williams Dennis, Bernard Andrew, Boral Leonard. Experience with uncrossmatched blood refrigerator in emergency department.. Trauma surgery & acute care open. 2018. DOI: 10.1136/tsaco-2018-000184.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.