MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.111.962993

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2011

Remote-controlled magnetic navigation and ablation with 3D image integration as an alternative approach in patients with intra-atrial baffle anatomy.

Ernst Sabine, Babu-Narayan Sonya V, Keegan Jennifer, Horduna Irina, Lyne Jonathan, Till Janice, Kilner Philip J, Pennell Dudley, Rigby Michael L, Gatzoulis Michael A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Improvement in outcome of infants born with congenital heart defects has been accompanied by an increasing frequency of late arrhythmias. Ablation is difficult because of multiple tachycardias in the presence of complex anatomy with limited accessibility. We report on remote-controlled ablation using magnetic navigation in conjunction with 3D image integration in patients with previous intra-atrial baffle procedures.

METHODS AND

RESULTS

Thirteen patients (8 male; age, 30.5±8 years) with supraventricular tachycardia (SVT) underwent catheter ablation. Group A had a medical history of a Mustard or Senning operation, whereas group B had undergone total cavopulmonary connection. A total of 26 tachycardias were treated in 17 procedures (median cycle length of 280 ms). Group A patients had more inducible SVTs than group B, and all index SVTs were located in the remainder of the morphological right atrium in all but 1 patient. Retrograde access through the aorta was performed and led to successful ablation, using magnetic navigation with a very low total radiation exposure (median of 3.8 minutes in group A versus 5.9 minutes in group B). Only 1 of 13 patients continued to have short-lasting SVTs despite 3 ablation procedures during a median follow-up time of >200 days.

CONCLUSIONS

Remote-controlled catheter ablation by magnetic navigation in combination with accurate 3D image integration allowed safe and successful elimination of SVTs, using an exclusively retrograde approach, resulting in low radiation exposure for patients after intra-atrial baffle procedures (Mustard, Senning, or total cavopulmonary connection).

Для цитирования: Ernst Sabine, Babu-Narayan Sonya V, Keegan Jennifer, Horduna Irina, Lyne Jonathan, Till Janice, Kilner Philip J, Pennell Dudley, Rigby Michael L, Gatzoulis Michael A. Remote-controlled magnetic navigation and ablation with 3D image integration as an alternative approach in patients with intra-atrial baffle anatomy.. Circulation. Arrhythmia and electrophysiology. 2011. DOI: 10.1161/circep.111.962993.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.