A multiparameter model for non-invasive detection of hypoglycemia.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Elvebakk Ole, Tronstad Christian, Birkeland Kåre I, Jenssen Trond G, Bjørgaas Marit R, Gulseth Hanne L, Kalvøy Håvard, Høgetveit Jan O, Martinsen Ørjan G
Аннотация
OBJECTIVE: Severe hypoglycemia is the most serious acute complication for people with type 1 diabetes (T1D). Approximately 25% of people with T1D have impaired ability to recognize impending hypoglycemia, and nocturnal episodes are feared.
APPROACH: We have investigated the use of non-invasive sensors for detection of hypoglycemia based on a mathematical model which combines several sensor measurements to identify physiological responses to hypoglycemia. Data from randomized single-blinded euglycemic and hypoglycemic glucose clamps in 20 participants with T1D and impaired awareness of hypoglycemia was used in the analyses.
MAIN RESULTS: Using a sensor combination of sudomotor activity at three skin sites, ECG-derived heart rate and heart rate corrected QT interval, near-infrared and bioimpedance spectroscopy; physiological responses associated with hypoglycemia could be identified with an F1 score accuracy up to 88%.
SIGNIFICANCE: We present a novel model for identification of non-invasively measurable physiological responses related to hypoglycemia, showing potential for detection of moderate hypoglycemia using a wearable sensor system.
APPROACH: We have investigated the use of non-invasive sensors for detection of hypoglycemia based on a mathematical model which combines several sensor measurements to identify physiological responses to hypoglycemia. Data from randomized single-blinded euglycemic and hypoglycemic glucose clamps in 20 participants with T1D and impaired awareness of hypoglycemia was used in the analyses.
MAIN RESULTS: Using a sensor combination of sudomotor activity at three skin sites, ECG-derived heart rate and heart rate corrected QT interval, near-infrared and bioimpedance spectroscopy; physiological responses associated with hypoglycemia could be identified with an F1 score accuracy up to 88%.
SIGNIFICANCE: We present a novel model for identification of non-invasively measurable physiological responses related to hypoglycemia, showing potential for detection of moderate hypoglycemia using a wearable sensor system.