m+Medelevator.RU
← Поиск публикаций
European journal of radiology · 2026

Clinical evaluation of deep learning accelerated 3D magnetic resonance cholangiopancreatography at 1.5 T and 3 T.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jambor Ivan, Dhami Ranjodh S, Parameswaran Madhangi, Milshteyn Eugene, Gaddipati Ajeetkumar, Thomas Mary, Guidon Arnaud, Cashen Ty, Rawal Miraj, Nakrour Nabih, Tabari Azadeh, Huang Susie Y, Tempany-Afdhal Clare, Harisinghani Mukesh G, Cochran Rory L

Аннотация

OBJECTIVE: Routine clinical 3D magnetic resonance cholangiopancreatography (MRCP) is typically performed either as lower resolution breath-hold (BH) acquisition or higher resolution triggered navigator breathing (NAV) acquisition with a longer acquisition time, potentially limiting clinically applicability. Our aim was to evaluate the clinical feasibility of MRCP obtained using a new deep learning acceleration approach, Sonic DLTM 3D (SDL), as compared to the standard 3D MRCP..

MATERIAL AND METHODS: Sixty-four and 32 patients underwent 1.5 T and 3 T MRCP scans, respectively. The standard 3D MRCP was obtained using a BH and NAV. Two SDL MRCP acquisitions for each magnetic field were performed with BH and scan times of 11-17 s, utilizing the SDL based acquisition and reconstruction technique. Three radiologists visually evaluated all MRCP datasets for 4 different features: overall image quality, image noise, image sharpness and artifacts. Differences were compared using the Wilcoxon matched-pairs signed rank and chi-squared tests.

RESULTS: At both field strengths (1.5 T and 3 T) the proportion of overall image quality scores of 3 or higher (good, very good and excellent) and proportion of cases with reduced artifacts were better (p < 0.05) for both SDL MRCP acquisitions compared to the standard with NAV or BH. However, SDL MRCP was not superior to the standard MRCP technique for all evaluated feature categories and scoring varied between readers.

CONCLUSION: SDL MRCP demonstrated improved image quality consistency and scan time, however, variations between radiologists in quality scores were present, underlying the need for future development and validation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты