MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2022.05.014

Медицинская библиотека · International journal of cardiology · 2022

Development of atrioventricular and intraventricular conduction disturbances in patients undergoing transcatheter aortic valve replacement with new generation self-expanding valves: A real world multicenter analysis.

Castro-Mejía Alex F, Amat-Santos Ignacio, Ortega-Armas Maria E, Baz Jose A, Moreno Raúl, Diaz Jose F, Travieso Alejandro, Jimenez-Quevedo Pilar, Santos-Martínez Sandra, McInerney Angela, Galeote Guillermo, Díaz Victor Alfonso Jimenez, Garrido Jessica Roa, Tirado-Conte Gabriela, Barrero Alejandro, Marroquin Luis, Nuñez-Gil Ivan, Gonzalo Nieves, Fernandez-Ortiz Antonio, Escaned Javier, Nombela-Franco Luis

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR.

METHODS AND

RESULTS

Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro (n = 130), Acurate-neo (n = 79), Portico (n = 75) and Allegra (n = 60)] were included. An analysis of baseline, post-TAVR and pre-discharge ECG and procedural aspects were centrally performed. A significant increase in baseline PR interval (169.6 ± 28.2 ms) and QRS complex width (101.7 ± 25.9 ms) was noted immediately post-TAVR (188.04 ± 34.49; 129.55 ± 30.02 ms), with a partial in-hospital reversal (179.4 ± 30.1; 123.06 ± 30.94 ms), resulting in a net increase at hospital discharge of 12.6 ± 38.8 ms and 21.4 ± 31.6 ms (p < 0.001), respectively. The global incidence of new onset persistent HDCD at hospital discharge was 46.3%, with 17.7% of patients requiring PPM. Independent predictors of new onset HCDC at hospital discharge were valve recapture (OR: 2.8; 95% IC: 1.1-7.2, p = 0.033) and implantation depth ≥ 6 mm (OR: 1.9 05% IC 1.1-3.3, p = 0.015), while higher implantation (<3 mm (OR: 0.3, 95% IC 0.1-0.7, p = 0.014) and use of Acurate-Neo valve (OR: 0.4; 95% IC 0.2-0.8, p = 0.009) were protective factor.

CONCLUSIONS

New generation self-expanding aortic valves were associated with a significant increase in PR and QRS interval at hospital discharge leading to a very high rate of HDCD. While valve recapture and implantation depth were independent predictors for the occurrence of HDCD, use of Accurate-Neo valve was a protective factor.

Для цитирования: Castro-Mejía Alex F, Amat-Santos Ignacio, Ortega-Armas Maria E, Baz Jose A, Moreno Raúl, Diaz Jose F, Travieso Alejandro, Jimenez-Quevedo Pilar, Santos-Martínez Sandra, McInerney Angela, Galeote Guillermo, Díaz Victor Alfonso Jimenez, Garrido Jessica Roa, Tirado-Conte Gabriela, Barrero Alejandro, Marroquin Luis, Nuñez-Gil Ivan, Gonzalo Nieves, Fernandez-Ortiz Antonio, Escaned Javier, Nombela-Franco Luis. Development of atrioventricular and intraventricular conduction disturbances in patients undergoing transcatheter aortic valve replacement with new generation self-expanding valves: A real world multicenter analysis.. International journal of cardiology. 2022. DOI: 10.1016/j.ijcard.2022.05.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.