MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcmg.2012.07.016

Медицинская библиотека · JACC. Cardiovascular imaging · 2012

Anatomic localization of rapid repetitive sources in persistent atrial fibrillation: fusion of biatrial CT images with wave similarity/cycle length maps.

Ravelli Flavia, Masè Michela, Cristoforetti Alessandro, Del Greco Maurizio, Centonze Maurizio, Marini Massimiliano, Disertori Marcello

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to investigate the anatomic distribution of critical sources in patients with atrial fibrillation (AF) by fusion of biatrial computed tomography (CT) images with cycle length (CL) and wave similarity (WS) maps.

BACKGROUND

Experimental and clinical studies show that atrial fibrillation (AF) may originate from rapid and repetitive (RR) sources of activation. Localization of RR sources may be crucial for an effective ablation treatment. Atrial electrograms showing rapid and repetitive activations can be identified by combining WS and CL analysis.

METHODS

Patients with persistent AF underwent biatrial electroanatomic mapping and pre-procedural CT cardiac imaging. WS and CL maps were constructed in 17 patients by calculating the degree of repetitiveness of activation waveforms (similarity index [S]) and the cycle length at each atrial site. WS/CL maps were then integrated with biatrial 3-dimensional CT reconstructions by a stochastic approach.

RESULTS

Repetitive sources of activation (S ≥ 0.5) were present in most patients with persistent AF (94%) and were mainly located at the pulmonary veins (82% of patients), at the superior caval vein (41%), on the anterior wall of the right atrium (23%), and at the left atrial appendage (23%). Potential driver sources showing both rapid and repetitive activations (CL = 140.7 ± 25.1 ms, S = 0.65 ± 0.15) were present only in a subset of patients (65%) and were confined to the pulmonary vein region (47% of patients) and left atrial appendage (12%). Differently, the repetitive activity of the superior caval vein was characterized by a slow activation rate (CL = 184.7 ± 14.6 ms).

CONCLUSIONS

The identification and localization of RR sources is feasible by fusion of biatrial anatomic images with WS/CL maps. Potential driver sources are present only in a subset of patients with persistent AF and are mainly located in the pulmonary vein region.

Для цитирования: Ravelli Flavia, Masè Michela, Cristoforetti Alessandro, Del Greco Maurizio, Centonze Maurizio, Marini Massimiliano, Disertori Marcello. Anatomic localization of rapid repetitive sources in persistent atrial fibrillation: fusion of biatrial CT images with wave similarity/cycle length maps.. JACC. Cardiovascular imaging. 2012. DOI: 10.1016/j.jcmg.2012.07.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.