MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euq014

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2010

Ganglionated plexi ablation for longstanding persistent atrial fibrillation.

Pokushalov Evgeny, Romanov Alexander, Artyomenko Sergey, Turov Alex, Shugayev Pavel, Shirokova Natalya, Katritsis Demosthenes G

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To study the potential efficacy of ganglionated plexi (GP) ablation in the setting of longstanding persistent atrial fibrillation (AF).

METHODS AND

RESULTS

Anatomic ablation at the areas of GP in the left atrium was performed in 89 patients with symptomatic, drug-refractory, persistent AF (71 men, 56 +/- 7 years of age). In 29 patients, a second procedure by means of circumferential pulmonary vein (PV) isolation was performed, and 5 of them were subjected to a third circumferential ablation. At 16 +/- 7 months after the final ablation procedure, 53 (59.6%) of the 89 patients were in sinus rhythm in the absence of antiarrhythmic drug therapy, 5 (5.6%) patients had permanent AF, and 31 (34.8%) patients had paroxysmal AF. The long-term success rate for patients who underwent a single ablation procedure with only GP ablation was 38.2% over a follow-up of 24 +/- 3 months. Independent predictors of later arrhythmia recurrences were left atrial diameter [HR 1.039 (1.00-1.07), P = 0.028] and duration of AF prior to ablation [HR 1.116 (1.02-1.22), P = 0.008].

CONCLUSION

Ganglionated plexi ablation in chronic AF results in long-term maintenance of sinus rhythm in 38.2% of cases. Repeat procedures with circumferential isolation of all PV offer a success rate of 59.6% over a follow-up of 16 +/- 7 months.

Для цитирования: Pokushalov Evgeny, Romanov Alexander, Artyomenko Sergey, Turov Alex, Shugayev Pavel, Shirokova Natalya, Katritsis Demosthenes G. Ganglionated plexi ablation for longstanding persistent atrial fibrillation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2010. DOI: 10.1093/europace/euq014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.