Journal of endodontics · 2022
Minimal Detectable Width of Tooth Fractures Using Magnetic Resonance Imaging and Method to Measure.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Groenke Beth R, Idiyatullin Djaudat, Gaalaas Laurence, Petersen Ashley, Chew Hooi Pin, Law Alan, Barsness Brian, Royal Mathew, Ordinola-Zapata Ronald, Fok Alex, Aregawi Wondwosen, Nixdorf Donald R
Аннотация
INTRODUCTION: Vertical root fracture (VRF) in root canal-treated (RCT) teeth is a common cause of pain, bone resorption, and tooth loss. VRF is also difficult to diagnose and measure. Magnetic resonance imaging (MRI) has the potential to identify VRF due to beneficial partial volume averaging, without using ionizing radiation. This investigation aimed to describe the narrowest VRFs detectable based on MRI, using micro-computed tomography (microCT) as the reference standard and proposes a method using profile integrals to measure the widths of small VRFs.
METHODS: VRFs were induced in 62 RCT tooth root samples. All samples were imaged in a phantom using MRI and reference imaging was obtained using microCT. The stacks of 3-dimensional axial MRIs were assessed by 3 board-certified endodontists. Evaluators determined the most coronal slice within the stack that was discernible as the extent of the VRF. This slice was measured on correlated microCT sections to determine the minimum VRF width (μm) detectable using a profile integral-based method to measure small fractures and negate the effects of the point spread function.
RESULTS: Using profile integrals to measure VRF width was repeatable and resulted in estimates that were on average 1 μm smaller than known reference widths. Adjusted median VRF width detected using MRI was 45 μm (first quartile: 26 μm, third quartile: 64 μm).
CONCLUSION: Using profile integrals is a valid way to estimate small VRF width. The MRI approach demonstrated ability to repeatedly detect VRFs as small as 26 μm.
METHODS: VRFs were induced in 62 RCT tooth root samples. All samples were imaged in a phantom using MRI and reference imaging was obtained using microCT. The stacks of 3-dimensional axial MRIs were assessed by 3 board-certified endodontists. Evaluators determined the most coronal slice within the stack that was discernible as the extent of the VRF. This slice was measured on correlated microCT sections to determine the minimum VRF width (μm) detectable using a profile integral-based method to measure small fractures and negate the effects of the point spread function.
RESULTS: Using profile integrals to measure VRF width was repeatable and resulted in estimates that were on average 1 μm smaller than known reference widths. Adjusted median VRF width detected using MRI was 45 μm (first quartile: 26 μm, third quartile: 64 μm).
CONCLUSION: Using profile integrals is a valid way to estimate small VRF width. The MRI approach demonstrated ability to repeatedly detect VRFs as small as 26 μm.