m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Cardiology · 2009

Ablation of persistent atrial fibrillation using multielectrode catheters and duty-cycled radiofrequency energy.

Клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Scharf Christoph, Boersma Lucas, Davies Wyn, Kanagaratnam Prapa, Peters Nicholas S, Paul Vince, Rowland Edward, Grace Andrew, Fynn Simon, Dang Lam, Oral Hakan, Morady Fred

Аннотация

OBJECTIVES: The purpose of this study was to assess the efficacy and safety of a novel, multielectrode, duty-cycled radiofrequency ablation (RFA) system for long-standing persistent atrial fibrillation (AF).

BACKGROUND: RFA for persistent AF remains a lengthy and challenging procedure.

METHODS: In 5 European centers, 50 patients with long-standing persistent AF underwent RFA. A circular pulmonary vein (PV) ablation catheter was used for PV isolation. Complex fractionated atrial electrograms were targeted at the interatrial septum using a multiarray septal ablation catheter and in the left atrium using a multiarray ablation catheter.

RESULTS: During a mean total procedure time of 155 +/- 40 min, complete PV isolation and complex fractionated atrial electrogram ablation were achieved in all patients. In 50% of patients, redo ablation was performed using the same strategy and technology. There were no device-related adverse events. At 6 months, a 7-day Holter electrocardiogram showed >80% AF reduction in 40 of 50 patients (80%), and 32 of 50 (64%) were off antiarrhythmic drugs. At 20 +/- 4 months after the last procedure, 31 of 47 patients (66%) had a >80% reduction in AF burden, with 21 patients (45%) free of AF and off antiarrhythmic drugs.

CONCLUSIONS: This initial 50-patient multicenter study demonstrates a 80% short-term and 66% success rate at 20 months, with a low complication rate and a relatively short procedure time in patients with persistent AF using 3 anatomically specific multielectrode ablation catheters and low-energy duty-cycled radiofrequency energy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты