Transesophageal mediastinoscopy by submucosal endoscopy with mucosal flap safety valve technique.

Sumiyama Kazuki, Gostout Christopher J, Rajan Elizabeth, Bakken Timothy A, Knipschield Mary A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Indications for NOTES (natural orifice transluminal endoscopic surgery) studied so far are limited to intra-abdominal surgery.

OBJECTIVES

To determine the technical feasibility and the safety of transesophageal mediastinocosopy by using the submucosal endoscopy with mucosal flap safety valve (SEMF) technique.

DESIGN

Two-week survival study with 4 porcine models.

INTERVENTIONS: High-pressure carbon dioxide injection and balloon dissection created a large submucosal working space for insertion of a cap-fitted endoscope. The muscularis propria was resected inside the submucosal space, and the mediastinoscopy was performed by using the endoscope inserted via the myotomy site. The muscular defect was sealed with the overlying mucosal flap, and the mucosal entry site was closed with clips.

MAIN OUTCOME MEASUREMENTS: Repeated endoscopy and necropsy were performed 2 weeks after the procedure.

RESULTS

With the SEMF technique, the posterior mediastinum was successfully accessed in all animals. Three pigs survived 2 weeks without clinical complications, and the defects were completely sealed by the mucosal flap. One pig with proximal esophageal mediastinal entry managed under voluntary respiration was euthanized because of pleural injury.

CONCLUSIONS

The SEMF technique provided safe entry into the mediastinum, with a protective submucosal tunnel that prevented mediastinal soiling. Mid to distal esophageal access is safer than the higher level access. Mechanical ventilation might allow safer respiratory support.

Для цитирования: Sumiyama Kazuki, Gostout Christopher J, Rajan Elizabeth, Bakken Timothy A, Knipschield Mary A. Transesophageal mediastinoscopy by submucosal endoscopy with mucosal flap safety valve technique.. Gastrointestinal endoscopy. 2007. DOI: 10.1016/j.gie.2006.10.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.