MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jeae114

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2024

Left and right ventricular longitudinal systolic function following aortic valve replacement in the PARTNER 2 trial and registry.

Silva Iria, Ternacle Julien, Hahn Rebecca T, Salah-Annabi Mohamed, Dahou Abdellaziz, Krapf Laura, Salaun Erwan, Guzzetti Ezequiel, Xu Ke, Clavel Marie-Annick, Bernier Mathieu, Beaudoin Jonathan, Cremer Paul C, Jaber Wael, Rodriguez Leonardo, Asch Federico M, Weismann Neil J, Bax Jeroen, Ajmone Nina, Alu Maria C, Kallel Faouzi, Mack Michael J, Webb John G, Kapadia Samir, Makkar Raj, Kodali Susheel, Herrmann Howard C, Thourani Vinod, Leon Martin B, Pibarot Philippe

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Evaluation of left and right ventricular (RV) longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and RV longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30 days and 1 year after AVR.

METHODS AND

RESULTS

Left ventricular (LV) longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER 2A surgical AVR (SAVR) arm (n = 985) and from the PARTNER 2 SAPIEN 3 registry (n = 719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline was associated with increased risk of the composite of death, hospitalization, and stroke at 5 years [adjusted hazard ratios (HRs) for LV LS < 15%: 1.24, 95% confidence interval (CI) 1.05-1.45, P = 0.001; TAPSE < 14 mm: 1.44, 95% CI 1.21-1.73, P < 0.001; RV-PA coupling < 0.55 mm/mmHg: 1.32, 95% CI 1.07-1.63, P = 0.011]. Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5 years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95% CI 1.08-1.68, P = 0.009) but not with TAVR (HR: 1.12, 95% CI 0.88-1.42). Lower RV-PA coupling at 30 days showed the strongest association with cardiac mortality.

CONCLUSION

SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30 days were associated with inferior clinical outcomes at 5 years. In patients with LVEF < 50%, TAVR was associated with superior 5-year outcomes.

Для цитирования: Silva Iria, Ternacle Julien, Hahn Rebecca T, Salah-Annabi Mohamed, Dahou Abdellaziz, Krapf Laura, Salaun Erwan, Guzzetti Ezequiel, Xu Ke, Clavel Marie-Annick, Bernier Mathieu, Beaudoin Jonathan, Cremer Paul C, Jaber Wael, Rodriguez Leonardo, Asch Federico M, Weismann Neil J, Bax Jeroen, Ajmone Nina, Alu Maria C, Kallel Faouzi, Mack Michael J, Webb John G, Kapadia Samir, Makkar Raj, Kodali Susheel, Herrmann Howard C, Thourani Vinod, Leon Martin B, Pibarot Philippe. Left and right ventricular longitudinal systolic function following aortic valve replacement in the PARTNER 2 trial and registry.. European heart journal. Cardiovascular Imaging. 2024. DOI: 10.1093/ehjci/jeae114.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.