MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.biomac.6c00731

Медицинская библиотека · Biomacromolecules · 2026

Contrast Agent Design to Deliver Improved Ultrasound Echogenicity from Medical Devices: A Route to In-Ward Device Placement Tracking.

Stimpson Amy, Contreras Jerry, Roper Bryce, Caruana James W, Ahmed Ifty, Hege Cordula, Sefton Joseph, Whittington Abby R, Irvine Derek J

СтатьяПеревод пока не подготовлен

Аннотация

This work reports a scalable strategy for producing polymeric medical devices with enhanced ultrasound (US) echogenicity via tailored dispersant design to support safer image-guided medical device placement. Real-time US imaging offers an alternative to X-ray imaging, reducing radiation exposure while enabling accurate device positioning/monitoring. Previous studies showed that including bioabsorbable phosphate-based glass (PBG) microspheres into thermoplastic polyurethane (TPU) could improve echogenicity. However, aggregation and processing defects limited the performance. To address this, two classes of acid-functionalized dispersants were synthesized to improve the microsphere dispersion and compatibility with TPU. These, i.e., dodecenylsuccinic diacid (DDSD) and oligomeric methacrylate/acrylates prepared using acid-functionalized chain-transfer agents, were grafted onto PBG microspheres via dip-coating and thermal treatment. Successful surface modification was confirmed by separation testing, SEM, and XPS. TPU composites containing the coated microspheres were then extruded into catheter-like structures and shown to demonstrate enhanced, more uniform echogenicity under clinical US imaging conditions without compromising the mechanical properties.

Для цитирования: Stimpson Amy, Contreras Jerry, Roper Bryce, Caruana James W, Ahmed Ifty, Hege Cordula, Sefton Joseph, Whittington Abby R, Irvine Derek J. Contrast Agent Design to Deliver Improved Ultrasound Echogenicity from Medical Devices: A Route to In-Ward Device Placement Tracking.. Biomacromolecules. 2026. DOI: 10.1021/acs.biomac.6c00731.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.