Socket-residuum coupling integrity affects perception of external stimuli: Effects of altering the transtibial interface using vacuum-assisted suspension.

Kent Jenny A, Carnahan Kristin J, Major Matthew J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Relative movement between the socket and residual limb can impair function in prosthesis users. It is plausible that, in addition to its mechanical effect, the integrity of the socket-residuum interface influences the ability of an individual to sense tactile cues through the prosthesis. Vacuum-assisted suspension (VAS) has been shown to reduce relative movement at this interface, providing a means to test this premise. The purpose of this pilot study was to assess the effects of altering socket-residuum interface integrity through the VAS pressure level on the thresholds of perception of an externally applied vibration stimulus.

METHODS

Seven unilateral transtibial prosthesis users participated. Socket-residual limb integrity was altered using the VAS subatmospheric (vacuum) pressure level. Vibration perception tests were conducted at low, mid, and high vacuum levels, targeting 0, 8, and 19 in Hg respectively, and performed in partially loaded and fully loaded conditions. Vibration intensity was increased using a dial until participants delivered a verbal signal indicating it was perceptible, and the nominal intensity was recorded.

RESULTS

Intensity thresholds decreased (ie, sensitivity increased) from low to high vacuum settings when fully loaded ( P = 0.008). Differences when partially loaded were nonsignificant and variable across participants.

CONCLUSION

This study provides preliminary evidence that altering the integrity between the socket and residual limb by modifying the vacuum level affects sensation related to the external environment experienced through the prosthesis, although translation of these findings to real-world stimuli remains to be tested.

Для цитирования: Kent Jenny A, Carnahan Kristin J, Major Matthew J. Socket-residuum coupling integrity affects perception of external stimuli: Effects of altering the transtibial interface using vacuum-assisted suspension.. Prosthetics and orthotics international. 2023. DOI: 10.1097/pxr.0000000000000257.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.