Impact of the Individual Operator Experience and Learning Curve of a Novel Size Adjustable Cryoballoon.

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hayashi Yosuke, Miyazaki Shinsuke, Nitta Junichi, Inaba Osamu, Sagawa Yuichiro, Iwai Shinsuke, Sekiguchi Yukio, Inamura Yukihiro, Yamauchi Yasuteru, Goto Kentaro, Nishimura Takuro, Sasano Tetsuo

Аннотация

BACKGROUND: Cryoballoon ablation is less operator-dependent than radiofrequency ablation. Recently, size-adjustable cryoballoons (SA-CBs) have become available. We sought to analyze the individual baseline operator experience's impact on procedural results.

METHODS: This multicenter observational study included atrial fibrillation (AF) patients who underwent pulmonary vein (PV) isolation using SA-CBs capable of 28-mm or 31-mm balloon sizes. Experienced (E-group) or less experienced (LE-group) operators were defined as experiencing > 100 or ≤ 100 cryoballoon procedures, respectively.

RESULTS: Among 510 patients (67 ± 11 years, 355 men, 325 paroxysmal AF [PAF]) who underwent an SA-CB ablation, 240 and 270 were in the E-group and LE-group, respectively. All cryoballoon parameters were similar between the groups, except for a significantly higher 31-mm balloon isolation rate in the E-group than LE-group, especially for right superior PVs. Cryoballoon-related phrenic nerve injury occurred in 34 (6.7%) patients and tended to be higher in the LE-group than E-group (8.1% vs. 5.0%, p = 0.16). The AF freedom was comparable between the groups for both PAF and non-PAF patients. A total of 36(7.1%) patients underwent re-do procedures at 5.2 ± 2.6 months post-index procedure. The PV reconnection rate was significantly higher in the LE-group than E-group (27.1% vs. 8.9%, p < 0.01), and this trend was more pronounced for right PVs than left PVs.

CONCLUSIONS: In AF ablation using SA-CBs, the overall procedural efficacy and safety were comparable between the E-group and LE-group. However, 100 CB procedures seemed to still be in the middle of a learning curve for selecting the balloon size and balloon position, especially for right PVs.