Comparison of 6-lead smartphone ECG and 12-lead ECG in athletes and a genetic heart disease population.

Davis Angus J, Orchard John W, McGhie Daniel, Broadbridge Daniel, Raju Hariharan, La Gerche Andre, Puranik Rajesh, Gray Belinda, De Jongh Jennifer, Driscoll Tim, Orchard Jessica J

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Smartphone electrocardiograms (iECGs) are an innovative method of capturing transient arrhythmias that are occasionally experienced by athletes. This study aimed to assess the accuracy of a 6-lead iECG compared with 12-lead ECG in athletes and those with known genetic heart disease (positive controls).

RESEARCH DESIGN AND

METHODS

Each participant had a resting 12-lead ECG (supine) and a 30 s 6-lead iECG (seated) taken within 2 h. Manual measurements of heart rate, QTc, and PR intervals, and QRS duration were completed using digital calipers. Bland-Altman analysis was used to assess the quantitative agreement of measurements.

RESULTS

The 6-lead readings for heart rate were faster than the 12-lead in athletes (n = 233) and positive controls (n = 49). All other measurements were shorter in the 6-lead. QTc mean difference was smaller in the positive controls (4.7 ± 26.0 ms) than in athletes (12.5 ± 25.0 ms). The largest difference was in PR intervals, both in athletes (12.8 ± 17.7 ms) and positive controls (7.6 ± 18.9 ms). QRS duration had the smallest mean difference (0.6 ± 9.0 ms in athletes, 1.0 ± 12.7 ms in positive controls).

CONCLUSIONS

The 6-lead readings had reasonable agreement with the 12-lead ECG. A 6-lead iECG is a reasonable option to opportunistically capture arrhythmias that may occur infrequently, but should not replace a 12-lead if available.

Для цитирования: Davis Angus J, Orchard John W, McGhie Daniel, Broadbridge Daniel, Raju Hariharan, La Gerche Andre, Puranik Rajesh, Gray Belinda, De Jongh Jennifer, Driscoll Tim, Orchard Jessica J. Comparison of 6-lead smartphone ECG and 12-lead ECG in athletes and a genetic heart disease population.. Expert review of medical devices. 2024. DOI: 10.1080/17434440.2024.2443113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.