m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2024

Significance of the local largest bipolar voltage for the optimized ablation strategy using very high-power short duration mode.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Takigawa Masateru, Miyazaki Shinsuke, Yamamoto Tasuku, Martin Claire A, Nozaki Sayumi, Yamaguchi Junji, Kawamura Iwanari, Ikenouchi Takashi, Negishi Miho, Goto Kentaro, Shigeta Takatoshi, Nishimura Takuro, Takamiya Tomomasa, Tao Susumu, Goya Masahiko, Sasano Tetsuo

Аннотация

PURPOSE: Very high-power short-duration (vHPSD) ablation creates shallower lesions, potentially reducing efficacy. This study aims to identify factors leading to insufficient lesions during pulmonary vein antral isolation (PVAI) with vHPSD-ablation and to develop an optimized PVAI strategy using this technology.

METHODS: PVAI was performed on 41 atrial fibrillation patients using vHPSD-ablation (90 W/4 s). Lesion parameters were recorded and analyzed to identify predictors of insufficient lesions. An optimized PVAI strategy, based on these predictors, was tested in subsequent 42 patients.

RESULTS: In total, 3099 RF-applications, including 103(3.3%) insufficient lesions, were analyzed. First-pass PVAI was achieved in 19/40(47.5%) right PVs and 24/41(58.5%) left PVs. Multivariate analysis identified significant predictors of insufficient lesions: local largest bipolar voltage (Bi-V), average contact force, baseline impedance, impedance drop, temperature rise, inter-lesion distance (ILD), and anatomical location (carina or not). An ILD:4-6 mm increased the risk of insufficient lesions 2.2-fold, and lesions at the carina increased it 3.6-fold for both ILD < 4 mm and ILD:4-6 mm. Local largest Bi-V was the strongest predictor for insufficient lesions. The optimized PVAI approach, utilizing vHPSD-ablation with an ILD < 4 mm in non-carinal areas with Bi-V < 4 mV, and high-power ablation-index guided ablation (HPAI, 50 W, ablation-index:450-550) in remaining areas, achieved first-pass PVAI in 92.7% of right PVs and 88.1% of left PVs, using vHPSD-ablation in approximately 65% of total RF-applications. The optimized PVAI achieved significantly higher first-pass PVI rate (p < .0001) with shorter ablation time (p = .04).

CONCLUSION: Appropriate use of vHPSD and HPAI, based on local largest Bi-V and anatomical information, may achieve high first-pass PVAI rates in shorter ablation time with minimal energy delivery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты