Significance of the local largest bipolar voltage for the optimized ablation strategy using very high-power short duration mode.

Takigawa Masateru, Miyazaki Shinsuke, Yamamoto Tasuku, Martin Claire A, Nozaki Sayumi, Yamaguchi Junji, Kawamura Iwanari, Ikenouchi Takashi, Negishi Miho, Goto Kentaro, Shigeta Takatoshi, Nishimura Takuro, Takamiya Tomomasa, Tao Susumu, Goya Masahiko, Sasano Tetsuo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Very high-power short-duration (vHPSD) ablation creates shallower lesions, potentially reducing efficacy. This study aims to identify factors leading to insufficient lesions during pulmonary vein antral isolation (PVAI) with vHPSD-ablation and to develop an optimized PVAI strategy using this technology.

METHODS

PVAI was performed on 41 atrial fibrillation patients using vHPSD-ablation (90 W/4 s). Lesion parameters were recorded and analyzed to identify predictors of insufficient lesions. An optimized PVAI strategy, based on these predictors, was tested in subsequent 42 patients.

RESULTS

In total, 3099 RF-applications, including 103(3.3%) insufficient lesions, were analyzed. First-pass PVAI was achieved in 19/40(47.5%) right PVs and 24/41(58.5%) left PVs. Multivariate analysis identified significant predictors of insufficient lesions: local largest bipolar voltage (Bi-V), average contact force, baseline impedance, impedance drop, temperature rise, inter-lesion distance (ILD), and anatomical location (carina or not). An ILD:4-6 mm increased the risk of insufficient lesions 2.2-fold, and lesions at the carina increased it 3.6-fold for both ILD < 4 mm and ILD:4-6 mm. Local largest Bi-V was the strongest predictor for insufficient lesions. The optimized PVAI approach, utilizing vHPSD-ablation with an ILD < 4 mm in non-carinal areas with Bi-V < 4 mV, and high-power ablation-index guided ablation (HPAI, 50 W, ablation-index:450-550) in remaining areas, achieved first-pass PVAI in 92.7% of right PVs and 88.1% of left PVs, using vHPSD-ablation in approximately 65% of total RF-applications. The optimized PVAI achieved significantly higher first-pass PVI rate (p < .0001) with shorter ablation time (p = .04).

CONCLUSION

Appropriate use of vHPSD and HPAI, based on local largest Bi-V and anatomical information, may achieve high first-pass PVAI rates in shorter ablation time with minimal energy delivery.

Для цитирования: Takigawa Masateru, Miyazaki Shinsuke, Yamamoto Tasuku, Martin Claire A, Nozaki Sayumi, Yamaguchi Junji, Kawamura Iwanari, Ikenouchi Takashi, Negishi Miho, Goto Kentaro, Shigeta Takatoshi, Nishimura Takuro, Takamiya Tomomasa, Tao Susumu, Goya Masahiko, Sasano Tetsuo. Significance of the local largest bipolar voltage for the optimized ablation strategy using very high-power short duration mode.. Journal of cardiovascular electrophysiology. 2024. DOI: 10.1111/jce.16453.