BACKGROUND

Operative ultrasonography for orienting the direction of transection of the liver is often useful in obtaining an adequate disease-free surgical margin. We have devised a new technique for hepatectomy guided by needles inserted under ultrasonographic guidance.

METHODS

One hundred two hepatectomies were performed between January 1987 and September 1991, and the hepatectomy with this technique was begun in January 1989.

RESULTS

In 10 of 29 limited hepatectomies performed in the first phase of the period in which this technique was not available, disease-free surgical margin of less than 1 cm was left because of inadequately directed division. Disease-free surgical margin of more than 1 cm was left in 18 of 23 limited hepatectomies in the second phase of the period in which this technique was available. In the other five operations where disease-free surgical margin of less than 1 cm was left, carcinomas were located too close to the major hepatic vessels. The average blood loss during the limited hepatectomies was reduced by this technique. Two-year and 3-year survival of patients undergoing hepatectomy for hepatocellular carcinoma were more favorable in the second phase than in the first phase.

CONCLUSIONS

Although the difference between the two groups was not significant, this technique is useful in performing adequate transection of the liver.

Для цитирования: Izumi R, Shimizu K, Kiriyama M, Hashimoto T, Yagi M, Yamaguchi A, Nagakawa T, Miyazaki I. Hepatic resection guided by needles inserted under ultrasonographic guidance.. Surgery. 1993.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.