MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.b.31699

Медицинская библиотека · Journal of biomedical materials research. Part B, Applied biomaterials · 2010

Simple immersion of filter devices into an urokinase solution prevents fibrin net formation during carotid artery stenting.

Hamada Kazuhide, Matsushima Satoshi, Toma Naoki, Totani Takahiko, Toda Mitsuaki, Ogawa Satoru, Asakura Fumio, Sakaida Hiroshi, Iwata Hiroo, Taki Waro

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Slow-flow phenomenon is frequently observed during carotid artery stenting (CAS) with a filter embolic protection device. It results in technical difficulties and can lead to adverse neurological events. Flow impairment is thought to be caused by plaque entrapped by the filter and/or blood coagulation on the filter. Characteristics of heparin- or urokinase-treated polyurethanes were analyzed by surface plasmon resonance, and the fibrinolytic activity of the urokinase-treated filter of Angioguard XP was estimated by the fibrin plate assay. A filter membrane of Angioguard XP protection device was treated with a heparin or urokinase solution. In clinical studies, six and nine patients were treated by CAS using Angioguard XP modified with heparin and urokinase, respectively. Filter membranes were examined by scanning electron microscopy (SEM). From in vitro studies, it appeared that urokinase adsorbed and remained on the Angioguard XP filter, and its fibrinolytic activity was demonstrated even after washing with saline; heparin, however, was easily washed out from the surface. From clinical study, some filter pores were obstructed in all six patients in the heparin group and in three patients in the urokinase group. Fibrin net was found on the filter in five of six patients in the heparin group and in one of nine patients in the urokinase group. Treatment of an Angioguard XP filter with a urokinase solution is effective in preventing pore occlusion and may reduce occurrence of the slow-flow phenomenon.

Для цитирования: Hamada Kazuhide, Matsushima Satoshi, Toma Naoki, Totani Takahiko, Toda Mitsuaki, Ogawa Satoru, Asakura Fumio, Sakaida Hiroshi, Iwata Hiroo, Taki Waro. Simple immersion of filter devices into an urokinase solution prevents fibrin net formation during carotid artery stenting.. Journal of biomedical materials research. Part B, Applied biomaterials. 2010. DOI: 10.1002/jbm.b.31699.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.