Interferon-γ release assays and tuberculin skin testing for diagnosis of latent tuberculosis infection in healthcare workers in the United States.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dorman Susan E, Belknap Robert, Graviss Edward A, Reves Randall, Schluger Neil, Weinfurter Paul, Wang Yaping, Cronin Wendy, Hirsch-Moverman Yael, Teeter Larry D, Parker Matthew, Garrett Denise O, Daley Charles L, Tuberculosis Epidemiologic Studies Consortium

Аннотация

RATIONALE: IFN-γ release assays (IGRAs) are alternatives to tuberculin skin testing (TST) for diagnosis of latent tuberculosis infection. Limited data suggest IGRAs may not perform well for serial testing of healthcare workers (HCWs).

OBJECTIVES: Determine the performance characteristics of IGRAs versus TST for serial testing of HCWs.

METHODS: A longitudinal study involving 2,563 HCWs undergoing occupational tuberculosis screening at four healthcare institutions in the United States, where the average tuberculosis case rate ranged from 4 to 9 per 100,000 persons. QuantiFERON-TB Gold In-Tube (QFT-GIT), T-SPOT.TB (T-SPOT), and TST were performed at baseline and every 6 months for 18 months between February 2008 and March 2011.

MEASUREMENTS AND MAIN RESULTS: A total of 2,418 HCWs completed baseline testing, which was positive for 125 (5.2%) by TST, 118 (4.9%) by QFT-GIT, and 144 (6.0%) by T-SPOT. A baseline positive TST with negative IGRAs was associated with bacillus Calmette-Guérin (BCG) vaccination (odds ratio: 25.1 [95% confidence interval: 15.5, 40.5] vs. no BCG). Proportions of participants with test conversion during the study period were 138 of 2,263 (6.1%) for QFT-GIT, 177 of 2,137 (8.3%) for T-SPOT, and 21 of 2,293 (0.9%) for TST (P < 0.001 for QFT-GIT vs. TST and for T-SPOT vs. TST; P = 0.005 for QFT-GIT vs. T-SPOT). Of the QFT-GIT and T-SPOT converters, 81 of 106 (76.4%) and 91 of 118 (77.1%), respectively, were negative when retested 6 months later. There was negative/positive discordance for 15 of 170 (8.8%) participants by QFT-GIT and for 19 of 151 (12.6%) by T-SPOT when blood was drawn 2 weeks later.

CONCLUSIONS: Most conversions among HCWs in low TB incidence settings appear to be false positives, and these occurred six to nine times more frequently with IGRAs than TST; repeat testing of apparent converters is warranted.