MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jrr/rraf062

Медицинская библиотека · Journal of radiation research · 2025

Comparative analysis of kVCT- and MVCT-guided helical tomotherapy for total body irradiation: evaluation of process times and residual setup errors.

Omi Yuta, Yada Ryuichi, Hasegawa Tatsuya, Shishido Ken, Sakai Keita, Kinoshita Tomotaka, Nakamura Katsumasa, Itoh Yoshiyuki, Takeuchi Arisa

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

Helical tomotherapy-based total body irradiation (TBI) traditionally employs megavoltage computed tomography (MVCT) for image-guided setup; however, its 390 mm field of view (FOV) and long acquisition times constrain workflow efficiency and whole-body alignment. This study evaluated whether a newly implemented whole-body fan-beam kilovoltage CT (kVCT; 500 mm FOV) can streamline this process. In a retrospective study involving 14 patients treated with a Radixact X9 system (September 2021-September 2023), we timed the patient setup, imaging, registration, re-setup, and beam delivery for each upper-body (UB) and lower-body (LB) segment. Residual setup errors were measured along the lateral, longitudinal, and vertical axes. The kVCT shortened the initial setup cycle (setup + imaging + registration) from 25.4 ± 4.6 to 15.9 ± 3.3 min for UB and from 14.5 ± 3.8 to 9.4 ± 2.4 min for LB (P < 0.001 for both). The total fraction time, including delivery time, decreased from 71.8 ± 7.5 to 56.7 ± 5.3 min. When residual errors exceeded 5 mm, the additional time required for a second cycle was nearly halved with kVCT (7.3 vs. 14.3 min for UB; 4.8 vs. 8.2 min for LB). The kVCT maintained mean absolute residual errors below 2 mm in all axes, and every 95th-percentile value remained within the 5 mm tolerance recommended for tomotherapy-based TBI. These time savings are expected to reduce intrafraction motion and staff workload. Overall, whole-body kVCT enables faster, comprehensive image guidance while preserving accuracy, thereby streamlining tomotherapy-based TBI and reducing the burden on patients and clinical staff.

Для цитирования: Omi Yuta, Yada Ryuichi, Hasegawa Tatsuya, Shishido Ken, Sakai Keita, Kinoshita Tomotaka, Nakamura Katsumasa, Itoh Yoshiyuki, Takeuchi Arisa. Comparative analysis of kVCT- and MVCT-guided helical tomotherapy for total body irradiation: evaluation of process times and residual setup errors.. Journal of radiation research. 2025. DOI: 10.1093/jrr/rraf062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.